Find clear guides to boiler error codes, common faults and everyday problems, with simple steps to pinpoint the cause and fix it faster. Save time with practical help that explains what each warning means and how to act without guesswork. Ideal when you need a quick, easy solution and want to get your boiler working again.

How to eliminate error B17 in boiler Dietrich? Error: B17 Description: BL.PU ERROR – The parameters saved on the PCU electronic card have been altered Cause: Solution: Parameter error...

How to eliminate error B16 in boiler Dietrich? Error: B16 Description: Bl.Mal its – the electronic card its does not recognize Cause: Solution: Electronic card your incorrect for this...

How to eliminate error B15 in boiler Dietrich? Error: B15 Description: Bl.pres.gas – gas pressure too low Cause: Solution: Bad adjustment of the gas prisoner on the SCU 4...

How to eliminate error B14 in boiler Dietrich? Error: B14 Description: Bl. Water Fall – Water pressure is less than 0.8 bar Cause: Solution: Lack of water in circuit...

How to eliminate error B13 in boiler Dietrich? Error: B13 Description: Bl.com PCU BL.com PCU -D4 – Communication error with the SCU electronic card Cause: Solution: Notify the professional...

How to eliminate error B10 B11 in boiler Dietrich? Error: B10 B11 Description: Bl. Entrad bl abta. – The BL entrance of the PCU electronics card is open...

How to eliminate error B09 in boiler Dietrich? Error: B09 Description: Bl.inv. L-N Cause: Solution: Notify the professional to take care of the maintenance of the apparatus More tips...

How to eliminate error B08 in boiler Dietrich? Error: B08 Description: Open bl.rl – The RL entrance of the PCU electronic card is open Cause: Solution: Parameter error 4...

How to eliminate error B07 in boiler Dietrich? Error: B07 Description: Bl.imp.ret. – The maximum difference between the driving and return temperature has been exceeded Cause: Solution: The water...

How to eliminate the B02 error in boiler Dietrich? Error: B02 Description: Bl. Drift Cald. – The increase in the output temperature has exceeded its maximum limit Cause: ...

How to eliminate error B01 in boiler Dietrich? Error: B01 Description: BL.MAX CALD – The maximum driving temperature has been exceeded Cause: Solution: The water flow is insufficient in...

How to eliminate error B00 in boiler Dietrich? Error: B00 Description: Bl.crc.psu – The PSU electronic card is poorly configured Cause: Solution: Parameter error on the PSU 4 electronic...