How to eliminate F11 error in boiler Sime?
- Error: F11
- Description: Indicates that there is an anomaly due to lack of water circulation. The lack of water circulation is detected whenever the temperature increase read by the heating probe is greater than 5 ° C per second. If so, the boiler stops, and does not restart until the temperature in the heating probe descends to less than 45 ° C.
- Cause:
- Solution: It is necessary to unblock or replace the water circulation pump. This work must do it a qualified technician.
More tips
If you fail to solve the boiler Sime error, we recommend that you contact the technical or specialist service. Most likely, you need a boiler review and, if necessary, repair. If you do not feel comfortable doing this type of repairs, we strongly recommend that you contact a professional.
Other error codes in Sime boiler

Troubleshoot error code “F10” in Sime boiler
How to eliminate F10 error in boiler Sime? Error: F10Description: Indicates an anomaly due to low water pressure. The prisoner detects that there are less than 0.5 bars and the ...

Troubleshoot error code “F09” in Sime boiler
How to eliminate F09 error in boiler Sime? Error: F09Description: Indicates a problem in the stagnant-open configuration, possibly an anomaly in the X15 card connector wiring. The boiler stops.Cause: Solution: ...

Troubleshoot error code “F08” in Sime boiler
How to eliminate F08 error in boiler Sime? Error: F08Description: Indicates an anomaly in the air pressure with the stopped fan. This occurs when the boiler, while working, detects the ...