- Error: “F53”
- Description: Failure in the circulating flow sensor.
- Cause: This error can be due to several reasons, such as insufficient gas flow pressure, wet or clogged filter cap of the Venturi tube, damaged circulating flow sensor, or clogged internal pressure measurement point in the Venturi tube.
- Solution: Below, we detail the steps to follow to solve this problem.
When your Vaillant boiler displays the error code “F53”, it’s time to pay attention and take action to solve the problem. This error can be an obstacle to the proper functioning of your heating and hot water system, but don’t worry, here we will explain how to address it.
Steps to Solve Error F53
Check the Gas Pressure
First, make sure the gas pressure is adequate. Insufficient pressure can be the root of the problem. If you’re unsure how to do this, it might be better to contact a professional.
Inspect the Filter Cap of the Venturi Tube
The filter cap of the Venturi tube may be wet or clogged. Check the filter and clean it if necessary. Make sure it’s dry before putting it back.
Check the Circulating Flow Sensor
The circulating flow sensor might be damaged. If you have technical knowledge, you can try to check its status, but if not, it’s advisable to have a qualified technician do it for you.
Clean the Venturi Tube
The internal pressure measurement point in the Venturi tube might be clogged. It’s important not to use lubricants on the Venturi tube’s O-ring when trying to clean it, as this could worsen the problem.
Contact a Professional
If the problem persists after following these steps, it’s most advisable to contact a qualified technician. They will be able to diagnose and solve the problem efficiently.
Additional Tips
- Regular Maintenance: Performing regular maintenance on your boiler can prevent this type of errors.
- User Manual: Consult your Vaillant boiler’s manual for more details on the F53 error and specific brand recommendations.
Remember, although some problems can be solved by following simple steps, it’s always b