A Chaffoteaux boiler displaying 1 08 usually indicates low pressure in the heating circuit; 5 01 means no flame has been detected on models using that numbering system. However, the meaning depends on the model: a Niagara Delta does not necessarily share the diagnostic system used by an Inoa Green. You can read the pressure, record the warning and look for external signs, but faults involving gas, combustion, electronics or internal circulation require an appropriately qualified engineer.
If you have a problem with your boiler, you can use our free error code finder. It can help you identify errors and understand how they can be resolved easily and effectively.
The model changes how the warning should be read
Chaffoteaux has used numerical displays, three-character codes and combinations of indicator lights. An Inoa Green may show messages such as 1 01 or 5 P3; certain Niagara Delta models use individual numbers, while some Elexia Confort boilers report faults through lights. There is no universal table that reliably covers all these systems without first identifying the appliance.
The useful identification is the full model designation found in the documentation or on a label accessible from outside. The product family, output and version suffixes matter, not just the commercial name. A photograph of the controls and another of that identification preserve the context of the fault without removing the casing or searching for references inside the appliance.
Chaffoteaux belonging to the same group as Ariston explains some technical similarities, but it does not make the brands’ codes interchangeable. Nor does it justify applying any table published for a Pigma or Inoa to a Nectra Top 24 FF. If the display format does not match the documentation being consulted, that interpretation is unreliable, even when the number looks familiar.
Three-character codes and their limitations
On the Inoa Green, the first digit identifies the area involved: group 1 covers the main heating circuit; 2, domestic hot water; 3, internal electronics; 4, external electronics; 5, ignition and flame detection; and 6, air intake and flue gases. This classification provides direction, not a diagnosis of which component needs repair.
Spacing also matters when recording the message. On a range that uses this convention, 108 and 1 08 may represent the same warning; however, 1 P1 is not 1 01. The letter P identifies warnings on the Inoa Green, rather than necessarily indicating a final lockout. Nevertheless, a recurring warning needs attention: continued operation does not prove that its cause has disappeared.
This table brings together the codes described for the Inoa Green family in the available technical information. Possible causes are diagnostic leads, not instructions to replace components. Applying them to another range requires checking the relevant manual, particularly when the version differs. The action column keeps user checks outside the appliance.
| Code | Description | Possible cause or scope | Safe action |
|---|---|---|---|
| 1 01 | Main circuit overheating. | Poor circulation, pump trouble or impaired heat transfer. | Stop using the boiler, allow it to cool and arrange inspection if the fault returns. |
| 1 03 | Insufficient circulation. | Air, hydraulic restrictions or a circulation pump fault. | Read the pressure and note external symptoms; internal diagnosis is for a professional. |
| 1 04, 1 05, 1 06, 1 07 | No individual description in the model-specific Inoa Green documentation examined. | A specific cause cannot safely be assigned. | Confirm the version and documentation before interpreting the code. |
| 1 08 | System filling requested. | Insufficient pressure in the heating circuit. | Read the pressure gauge and look for visible drips without working on the circuit. |
| 1 09 | Plausibility Test error. | The consistency of circuit readings needs investigation according to the version. | Do not assume it means excessive pressure; model-specific interpretation is required. |
| 1 10 | Open circuit or short circuit at the flow temperature sensor. | Sensor, connection or wiring. | Inspection by a qualified engineer. |
| 1 12 | Open circuit or short circuit at the return temperature sensor. | Sensor, connection or wiring. | Inspection by a qualified engineer. |
| 1 14 | Open circuit or short circuit at the outdoor sensor. | Outdoor sensor or its connection. | Look for external damage without touching connections; arrange professional inspection. |
| 1 16 | Underfloor heating thermostat open. | Operation or malfunction of the protective device on the underfloor heating circuit. | Do not bypass the protection; arrange diagnosis. |
| 1 P1 | Insufficient circulation warning. | A hydraulic issue that has not yet been identified. | Record when it appears and whether it recurs. |
| 1 P2, 1 P3 | No individual description in the specific documentation examined. | Undetermined. | Do not automatically give these codes the same meaning as 1 P1. |
| 2 05 | Domestic hot water inlet NTC sensor open. | Sensor or connection interruption. | Professional diagnosis of the sensing circuit. |
| 3 01 | Display EEPROM memory error. | Memory or electronic malfunction. | Reset only if the manual allows it; arrange inspection if it persists. |
| 3 02 | Communication error. | Internal communication, connection or electronic fault. | Do not open the appliance or buy a circuit board without diagnosis. |
| 3 03, 3 05, 3 06, 3 07 | Main circuit board error. | An electronic fault requiring technical checks. | Professional inspection; the code alone does not establish which replacement part is needed. |
| 5 01 | No flame detected. | Supply, ignition or combustion detection issue. | Check for supplier notices of an interruption; do not work on the gas system. |
| 5 02 | Flame signal with the gas valve closed. | A detection, electronic or shut-off fault requiring investigation. | Stop using or resetting the boiler; arrange professional inspection. |
| 5 P1 | First ignition attempt failed. | The sequence has not established or recognised a flame. | Observe what follows without manually triggering further attempts. |
| 5 P2 | Second ignition attempt failed. | Continuing ignition difficulty. | Arrange inspection if it recurs or ends in lockout. |
| 5 P3 | Flame extinguished or lost. | Unstable combustion or detection; diagnosis is required. | Do not clean electrodes or dismantle combustion components. |
| 6 10 | Heat exchanger overheating. | A thermal or circulation issue requiring checks. | Do not disable protective devices; professional intervention is required. |
| 6 12 | Fan error. | Fan, control or connection issue. | Do not dismantle the fan or flue ducts. |
Messages that must not be transferred between ranges
Code 1 09 illustrates the risk of mixing tables: it is described as a plausibility check in the model-specific Inoa Green information, while other listings describe it as excessive pressure. These are not equivalent diagnoses. The pressure gauge provides useful information, but it does not justify draining water to clear a message whose meaning has not yet been confirmed.
A similar issue affects 1 04 to 1 07. Some general listings group them under insufficient circulation, but the available model-specific Inoa Green documentation gives no individual description. Acknowledging that lack of confirmation is more accurate than turning a common association into a certainty for every version.
Sensor, ventilation and calibration codes also circulate that cannot all be assigned to every Chaffoteaux boiler. The following meanings help identify differences in the documentation, rather than confirm their presence on a particular Nectra, Inoa or Niagara. Before taking action, their applicability to the model must be confirmed, including any associated figures or timings.
| Code | Description found in listings for other versions | Cause or limitation | Action |
|---|---|---|---|
| 102 | Pressure detector fault. | Sensor, connection or abnormal reading; meaning must be confirmed for the model. | Read the gauge; an engineer must check the detector. |
| 109 | Excessive pressure in some general listings. | This differs from the model-specific description of 1 09 for Inoa Green. | Do not interpret without the correct version’s manual. |
| 201 | Domestic hot water sensor fault. | Sensor or connection; not interchangeable with 2 05 on another configuration. | Professional diagnosis. |
| 203 | Cylinder sensor fault. | Applies only to configurations matching that description. | Confirm that a cylinder is fitted and consult the specific documentation. |
| 504 | Repeated flame loss. | Some listings specify six occurrences; that counter is not universal. | Professional inspection of combustion and flame detection. |
| 605 | Flue gas sensor fault. | Sensor or connection, if the model has this monitoring function. | Do not work on the flue system. |
| 610 | Open thermal protection in certain descriptions. | Inoa Green describes it as heat exchanger overheating. | Establish the cause; never bypass the protective device. |
| 611 | Ventilation or air intake fault. | Some listings mention a 20-minute lockout; confirm the version. | Do not assume waiting will resolve the underlying fault. |
| 612 | Fan or fan speed fault. | Details depend on the model’s control system. | Professional inspection of the assembly. |
| 801 | Combustion self-calibration requested. | Only applies to appliances with this function and coding. | Procedure reserved for an engineer. |
| 802 | Self-calibration failure. | Calibration has not completed; the cause requires diagnosis. | Do not repeat adjustments through the installer menu. |
| 803 | Incorrect output configuration. | The association with parameter 229 requires model confirmation. | Professional configuration only. |
| 804 | Communication decoupling required in certain solar or hybrid installations. | This does not identify a universal accessory or part number. | An appropriately qualified engineer must check the installation diagram. |
The Niagara Delta uses a different numbering system
On certain Niagara Delta models, 1 identifies an overheating shutdown and 3 indicates an ignition fault. They must not be intuitively converted into 101 or 301: adding digits changes the code and may lead someone to investigate the electronics when the problem belongs to another system.
Niagara 23 CF, Delta 24 FF and Delta 30 FF versions should not be treated as identical appliances either. Components and monitoring functions may differ. This table distinguishes the fault families, but exact thresholds and technical checks require the documentation for the precise version.
| Code | Description on Niagara Delta | Possible cause | Safe action |
|---|---|---|---|
| 1 | Safety shutdown due to overheating. | Poor circulation or a thermal problem. The available listing specifies above 105 °C for the versions described. | Stop using the appliance and arrange inspection if the fault recurs. |
| 3 | Ignition failure associated with the ionisation circuit. | Ignition or flame recognition problem. | Do not work on electrodes or the gas valve. |
| 7 | No circulation or insufficient circulation. | A flow-to-return temperature difference above 40 °C is described for the relevant versions. | Professional hydraulic diagnosis. |
| 8 | Circulation fault while the burner is operating. | Insufficient circulation during operation. | Do not keep resetting. |
| 9 to 14 | Heating or domestic hot water thermistor faults. | Open circuit or short circuit; individual assignments depend on the manual. | Do not replace a sensor based solely on this range of codes. |
| 19 to 24 | Faults involving flue gas evacuation or ventilation. | Depend on the version and individual code. | Professional inspection; do not dismantle ducts. |
| 25 / 26 | Cylinder thermistor fault. | Sensor or connection in the storage system. | Technical inspection. |
| 31 / 32 | Communication fault between circuit boards. | Connections or electronics. | Do not assume both boards need replacement. |
The distinction between 7 and 8 matters because they describe different circumstances: the first relates to the temperature difference between flow and return; the second concerns circulation while the burner is running. They may share causes, but neither proves the pump is faulty. Replacing it without checking the circuit may leave the original problem unresolved.
Pressure readings provide evidence, not a complete diagnosis
Code 1 08 concerns the closed heating circuit, not simply a weak flow from a tap. As a guide, the available information commonly places cold pressure between 1 and 1.5 bar, with 1.5 bar specified in certain Chaffoteaux instructions. The manual’s value takes precedence: a generic figure should not be imposed on every installation.
A reading below 1 bar may indicate insufficient pressure on the appliances described, while a reading approaching 3 bar warrants attention for possible overpressure. These figures are not filling or draining instructions. You can observe the gauge when the boiler is cold and look for visible dampness beneath radiators or accessible connections, but do not work on the pressurised circuit, safety valve or expansion vessel.
A pump that fails to move water properly can cause overheating without any water loss. Conversely, repeated pressure drops may result from a leak or discharges linked to another fault. Circulation and pressure are not interchangeable. Persistent water loss should not be dismissed as ordinary evaporation from a closed circuit either.
If pressure drops again after work has been carried out, repeatedly adding water does not demonstrate that the problem is fixed. Recording the cold reading and how it changes during normal operation is more useful, without forcing tests. Continued hot water delivery does not guarantee safe operation: behaviour depends on the design and the active lockout.
Ignition and flue faults define the intervention limit
Code 5 01 reports that a flame has not been recognised, but does not by itself distinguish a supply interruption from an ignition problem or detection fault. You can check whether the supplier has announced an interruption. There is no need to light other appliances to test the gas or dismantle electrodes: combustion work belongs to a professional.
Code 5 02 calls for particular caution because it reports a flame signal when the valve should be closed. It does not automatically prove a circuit board fault, nor rule out a gas shut-off problem. The appropriate response is to stop using the boiler and arrange inspection, without repeated resets to see whether the message disappears.
If you smell gas, do not press reset, operate electrical switches or use flames. Move away from the area and report the incident to the gas emergency service from a safe place; if there is immediate danger in Spain, call 112. If a carbon monoxide alarm sounds or dizziness and headache occur while the appliance is operating, go outside and seek help.
Fan, air intake and flue gas warnings cannot be resolved by removing parts either. An obvious external obstruction may be visible from a safe position, without approaching a hot terminal or working at height. Dismantling a duct or internally cleaning a fan interferes with a safety-critical system: that work requires a qualified professional.
A reset is not a repair
A reset clears or releases certain lockouts when the control system permits an attempt, but it does not fix a leak, a seized pump or unstable combustion. It should only be used as instructed for the model, with no gas smell, signs of flue gas leakage or other danger. One permitted attempt provides more useful information than a succession of resets.
Some instructions cite a maximum of five resets within 15 minutes. That limit is not a recommendation to use every attempt, nor does it apply automatically to all ranges. If the same warning returns after a permitted reset, do not keep trying. Repeatedly switching off the power is not advisable either: it may erase useful context without resolving the cause.
Before any authorised restart, keeping a photograph preserves whether 5 P3 appeared before 5 01, whether the pressure changed or whether the fault occurred when a tap was opened. That sequence helps distinguish an isolated symptom from a pattern. Recording does not mean recreating the fault: there is no need to trigger more starts to document it.
A repair estimate should follow diagnosis, not a number
A sensor reported as open may have a connection problem; interrupted communication does not prove a circuit board is unusable. Buying a replacement before establishing the cause can therefore add expense without restoring service. The code identifies an abnormal condition, rather than automatically instructing replacement of the component named in its description.
There is no single price that can be inferred from the display. Cost depends on the confirmed cause, the compatible part, labour and the terms covering travel and diagnosis. Before agreeing to a visit, it is worth establishing in writing which charges are separate and whether the diagnostic fee is deducted if the repair goes ahead; neither should be assumed.
When deciding between repair and replacement, overall condition, parts availability and the scale of the repair matter alongside the price. If warranty cover might apply, checking its terms before authorising work helps avoid compromising the claim process. There is no need to open the boiler to provide the model, code and symptoms needed for an initial assessment.
Accurate information prevents unnecessary intervention
Diagnosis starts on firmer ground with the full model, a readable photograph of the message and a description of when the appliance stops. Cold pressure, visible drips and the distinction between a heating failure and a hot water failure add context. These details reduce uncertainty, although they do not replace the measurements an engineer must take.
The important decision is not how to make the number disappear at any cost, but how to distinguish an external check from a repair. If the lockout returns, pressure changes sharply or a combustion safeguard operates, the next step belongs to a professional. Respecting the safety lockout protects both people and the appliance itself.
This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.
Ceramic hob7 days agoF error on a Siemens hob: what it means and what to do
Oven6 days agoWhirlpool oven F01 error: what it means and what to do
Bosch6 days agoBosch oven E05-32 error: what to check and when to stop
Electrolux6 days agoElectrolux oven F102 error: causes and safe troubleshooting
Coffee machine3 days agoPhilips coffee machine error 05: what it means and what to do
Electrolux7 days agoElectrolux induction hob E3 error: meaning and safe next steps
Coffee machine3 days agoJura coffee machine error 8: what to do and repair costs
Coffee machine3 days agoSaeco coffee machine error 1: what it means and what to do
Bosch7 days agoError 32 on a Bosch induction hob: what to do
Microwave5 days agoError 2 on a Whirlpool microwave: causes and what to do
Coffee machine3 days agoPhilips coffee machine error 1: causes and safe cleaning
Fridge4 days agoLG fridge FF error: what it means and what to do