Manaut boiler error 01: causes and safe checks
An ignition fault does not automatically mean a failed circuit board. The model and response to a reset matter.

Error 01 on a Manaut boiler indicates an ignition failure lockout in the Myto Condens and Midas Eco ranges covered here: the appliance cannot establish a flame or does not receive a valid signal confirming its presence. Depending on the model and display, it may appear as Er 01, 01E or E01. It does not, on its own, prove that the circuit board has failed. Provided there is no smell of gas or other unusual warning sign, household checks are limited to identifying the appliance, checking for supply interruptions and attempting one reset in accordance with its manual. If it locks out again, a qualified engineer needs to investigate.
If you have a problem with your boiler, you can use our free error code finder. It helps you identify errors and find clear, practical troubleshooting information.
The boiler locks out because it cannot confirm ignition
To provide heating or hot water, the boiler needs to light the burner and confirm that combustion has been established correctly. If that confirmation does not arrive, the system stops operating. The warning therefore describes a safety condition, not an instruction to replace a particular component. The visible result is usually a loss of service, although the underlying cause may be outside the appliance or within it.
There is an important difference between failing to produce a flame and failing to detect one. In the first case, there may be a supply interruption or a problem with the ignition system. In the second, the signal confirming combustion does not reach the control correctly. Both situations can lead to the same lockout. The display shows the outcome of an unsuccessful attempt, but cannot, by itself, distinguish between those two situations.
This distinction helps prevent an unnecessary purchase. An electrode, a gas valve and a circuit board are not interchangeable solutions to be tried in turn for the same warning. Although all may feature in a professional investigation, the code does not identify the faulty part. Nor does it establish whether the repair will be straightforward, expensive or unnecessary without first checking the cause.
Er 01, 01E and E01 need an exact model name
On the Manaut Myto Condens, the ignition fault is described as Er 01 and may appear as 01E on a compatible remote control. The E01 notation is also used for the Midas Eco 24E and 28E. These variants share the stated meaning within those ranges, but must not be applied automatically to every appliance carrying the Manaut name or to all of its controls.
The full model name matters more than the appearance of the casing. Myto Condens, Myto Condens Inox and other versions within the family can differ in their controls and components. Identify the appliance using its manual or a label accessible from outside, without removing panels. A clear photograph of the display and model preserves the information needed to interpret the warning without relying on memory later.
The letter accompanying the number matters too. An L 01 warning must not be treated as an E01 lockout simply because they contain the same digits. On the Midas Eco, L 01 refers to a limitation associated with the primary circuit temperature during hot water production. Confusing the messages changes the diagnosis completely: the letters are part of the code, not a decorative detail on the screen.
Related codes help distinguish different faults
The following table separates ignition lockout from other warnings found in the ranges discussed here. The causes are indicative: they identify what needs investigation, not which part to buy. Where the same number has different descriptions across product families, the distinction between models is retained. The manual for the exact version remains the final reference for interpretation.
| Code | Description | Cause or area for investigation | Range or qualification |
|---|---|---|---|
| Er 01 / 01E | Ignition failure lockout | Gas supply, ignition or flame detection | Myto Condens; presentation depends on the appliance and control |
| E01 / 01E | Safety lockout due to ignition failure | Supply, electrodes, gas valve or ignition control | Midas Eco 24E and 28E |
| L 01 | Primary circuit limitation during hot water production | High temperature; may be associated with poor heat transfer | Midas Eco 24E and 28E; not equivalent to E01 |
| Er 02 / 02E / E02 | Safety thermostat activation | Overheating or circulation and temperature control problems | Check the notation for each range |
| Er 03 / 03E / E03 | General lockout | Internal fault requiring diagnosis; the code does not confirm a failed circuit board | Myto Condens and Midas Eco, depending on version |
| Er 04 / 04E / E04 | Insufficient pressure or lack of circulation | System water, pump or circulation | Must not be confused with ignition fault 01 |
| Er 05 | Fan control fault | Fan and its control system | Myto Condens |
| E05 / 05E | Flue pressure switch fault | Monitoring of flue gas evacuation | Midas Eco 24E and 28E |
| Er 06 / E06 / 06E | Heating temperature sensor fault | Temperature sensor or its connections | Depending on range and display format |
| Er 07 / E07 / 07E | Domestic hot water temperature sensor fault | Temperature sensor or its connections | Depending on range and display format |
| Er 08 / E08 / 08E | Outdoor sensor fault | Outdoor sensor, where fitted, or its connection | Depending on installed equipment |
| Er 09 | Open circuit at the flue temperature sensor | Flue temperature sensor or its circuit | Myto Condens, depending on version |
| Er 10 | Lockout triggered by the flue temperature sensor | Temperature condition detected in the flue gases | Myto Condens, depending on version |
| E11 / 11E | Unexpected flame detection | Flame signal outside the expected operating sequence | Availability depends on the range and control |
| Er 12 | Return temperature sensor fault | Return temperature sensor or its connections | Myto Condens, depending on version |
| Er 13 | Flow and return temperature difference greater than 40 °C | Circulation or heat transfer | Myto Condens, depending on version |
| Er 14 | Pump failure or primary circuit temperature above 105 °C | Circulation and temperature control | Myto Condens, depending on version |
| E14 / 14E | Circulation fault or excessive temperature rise | Pump, air or circuit restrictions; E14 is described with a temperature gradient above 2 K/s | Midas Eco 24E and 28E |
| Er 19 | Domestic cold water inlet sensor fault | Relevant sensor or its connection | Myto Condens, depending on version |
| E20 / E21 / E22 / E23 | Gas valve-related lockout | Valve and its electronic control | Midas Eco 24E and 28E |
| E24 | Combustion fault during ignition | Gas, flame detection, air intake or flue evacuation | Midas Eco 24E and 28E |
| Er 69 / E69 | Wiring error lockout | Electrical connections and checks reserved for an engineer | Depending on range |
| Li | Primary circuit limitation during hot water operation | Temperature regulation; does not automatically indicate a fault | Myto Condens, depending on version |
One particularly important mistake is to interpret E01 as low water pressure. In the ranges described here, that issue belongs to the 04 group, not 01. Another is to describe E05 on a Midas Eco as an ignition failure, when it has a different meaning. Matching numbers across brands do not justify transferring instructions from a Baxiroca boiler to a Manaut either.
Household checks stop at accessible controls
Before any reset attempt, conditions around the boiler must be normal: no smell of gas, no carbon monoxide alarm and no signs of abnormal combustion. If you smell gas, do not try to ignite or reset the boiler, operate electrical switches or create flames. Move away and contact the gas distributor’s emergency service or the local emergency number from a safe location. A carbon monoxide alarm also requires leaving the area and seeking help.
When none of those warning signs is present, it is useful to check whether the distributor has reported a supply interruption or whether other appliances had already lost service. There is no need to light another appliance as a test or operate gas valves to investigate. A household check can include observing an accessible, clearly identified valve, but not forcing it, dismantling it or working on regulators, meters or pipes.
The pressure gauge can also be read without opening the appliance. A cold pressure of 1 to 1.5 bar is a common reference for domestic systems of this type, although the value specified for the model and installation takes precedence. That reading provides context; it does not, by itself, explain lockout 01. An out-of-range pressure should be reported, not corrected through an improvised filling procedure.
The casing marks a clear boundary. Removing panels to clean electrodes, reposition tubes or inspect connectors goes beyond a household check. Measuring voltage, loosening connections or checking gas pressure is not appropriate either. These operations affect combustion and safety systems and require a qualified professional, suitable instruments and subsequent safety checks.
A reset may restore service, but does not prove a repair
A reset allows the appliance to leave lockout and attempt another operating sequence, provided its operating conditions are satisfied. It must be performed using the designated control and the instructions in the exact manual. Some versions use a button, while others use a selector position; there is no universal button-hold time that can safely be given for every Manaut boiler.
A single attempt, without warning signs and after identifying the correct procedure, can establish whether the incident was temporary. If the warning returns, repeated attempts or alternating resets with power interruptions are not appropriate. A lockout being resettable means the function is available, not that its cause has disappeared or that repeating it indefinitely is suitable.
If service returns, observe the boiler during normal use without deliberately triggering starts to test it. A recurrence when a hot tap is opened or the heating starts provides useful information. Working between episodes does not rule out an intermittent fault; if the appliance needs resets to keep providing service, it should be inspected rather than making resetting part of the household routine.
The electrode and circuit board are possibilities, not diagnoses
The ignition system produces the spark needed to start combustion. Flame detection then confirms that the burner has lit. A problem with the electrodes, their connections or the ionisation signal can result in lockout. In simple terms, ionisation provides the electrical signal used to recognise the flame; it cannot be assessed from the code alone.
The gas valve and its control are also possible causes. Establishing whether they receive and carry out the operating command correctly requires professional checks. It is not safe to infer this from a clicking noise or the sound of a spark. Nor should anyone remove covers to look for a flame: external sounds do not replace measurements or justify opening the combustion chamber.
The circuit board participates in the sequence, but attributing every 01 lockout directly to it is an unjustified leap. Similarly, an explanation presenting a coding connector as an automatic solution does not establish that it is the cause on a particular appliance. When descriptions conflict, what matters is diagnosis of the actual model and fault, not replacing whichever component is mentioned most often.
Useful observations to record before an inspection
The timing of the failure can reveal more than a general statement that the boiler does not work. A lockout during a hot water demand is not the same as one when the heating starts, and an incident after a supply interruption differs from repeated episodes with no apparent change. Recording that context helps locate the fault within the operating sequence without carrying out invasive tests.
A photograph of the code before resetting prevents information being lost if another warning appears later. Alongside the full appliance name, it is useful to keep the visible pressure gauge reading and explain whether service returned. There is no need to recreate the fault to document it: observation during normal use is enough, and repeated starts may reveal less than an accurate account of the first incident.
If the appliance still has warranty cover or a maintenance agreement, check the conditions before authorising work or buying components. Opening it yourself may complicate the assessment of a claim and adds unnecessary risk, although it does not follow that any opening automatically cancels all cover. Coverage must be checked against its terms, rather than assumed from general rules applied to every installation.
The cost depends on the cause, not the number on the display
There is no single price for resolving this lockout. An external supply interruption does not involve the same work as a flame detection fault, a valve issue or a circuit board failure. An advertised spare-part price is not the cost of a completed repair either: diagnosis, travel and labour may form part of the bill, alongside safety checks and applicable taxes.
Before accepting an intervention, establish what the diagnostic service includes and whether its charge is deducted if the repair goes ahead. It should also be clear whether the quotation includes everything necessary to return the appliance to service. Without those details, comparing two prices can be misleading: the price of a part alone is not comparable with a complete, tested repair.
Choosing between repair and replacement requires assessing the overall condition, fault history, availability of the correct spare and total installed cost of the alternative. A single 01 lockout does not, by itself, justify replacing the boiler. Finding an apparently compatible part from another brand is not enough either: the reference and version must be verified before a professional is authorised to fit it.
Restoring service means respecting the reason for the lockout
A sensible response to this warning is limited but useful: identify exactly what the display shows, rule out warning signs that prevent any attempt, and use only the prescribed reset when appropriate. If the boiler locks out again, the next stage is no longer a household task. Inspection belongs with an engineer qualified to work on gas appliances, who can distinguish between supply, ignition, detection and control issues.
No smell of gas does not make internal work safe, and temporary operation after a reset does not certify that everything is resolved. The aim is not to erase a number, but to restore heating and hot water with the protective systems functioning. On a Manaut with repeated ignition failures, respecting the lockout prevents trial and error from replacing diagnosis and supports an informed decision before spending money on parts or a replacement appliance.
This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.
Balay6 days agoHow to disable the child lock on a Balay Varioperfect washing machine
Balay6 days agoHow to disable the child lock on a Balay Varioperfect washer
Balay6 days agoBalay washing machine symbols and errors: what they mean
Balay6 days agoFlot button on Balay washing machine: meaning and solution
Kitchen plate4 days agoBalay induction hob: common errors and solutions
Balay5 days agoBalay hob with E1 error: what it means and how to fix it
Balay4 days agoBalay hob error F: causes and safe solutions
Balay6 days agoBalay 3TS61 error test: what to do
Balay6 days agoBalay 3VC dishwasher error codes: solutions
Balay6 days agoHow to fix the E18 error code on a Balay washing machine
Balay5 days agoBalay hob error 31: meaning and safe solution
Kitchen plate6 days agoHow to fix the E error on a Balay induction hob