Baxi heat pump faults: 35 codes and what you can check
35 Baxi fault codes explained, with model-specific differences and clear limits for safe checks at home.

A warning on a Baxi heat pump may indicate an incorrect temperature reading, insufficient water circulation, an external lockout or an outdoor unit fault. The code must be read alongside the model: it does not, on its own, identify a part that needs replacing. If H02.07, H02.23 or E02.24 appears, you can check the displayed pressure and observe the equipment without dismantling it; internal checks require a qualified technician.
If you have a problem with your heat pump, you can use our free error code finder. It helps you identify faults and find straightforward, effective guidance on resolving them.
The model determines what each warning means
The available reference material brings together codes used in the Platinum BC iPlus family and others specifically identified for Platinum BC iR32. Although they share a manufacturer and may look similar on the display, they are not a universal catalogue for every Baxi heat pump. The interpretation must be checked against the installed unit’s manual, particularly where the range, controller or system configuration differs.
The table brings together 35 distinct identifiers found in the reference material. Four are explicitly identified for Platinum BC iR32: H06.28, H06.06, H06.07 and H06.36. That distinction matters: a communication fault and a refrigerant pressure protection event require different investigations, even though both can stop the heating. A matching code does not replace a compatibility check against the specific equipment.
Before acknowledging or clearing a message, it helps to take a photograph showing the complete code, including letters, dots and zeros. Note the model too, and whether the problem affects heating, cooling or domestic hot water, abbreviated as DHW. With those details, diagnosis starts from verifiable information, rather than an approximate memory of the warning or an assumed equivalent from another brand.
The 35 codes and the faults they help locate
The description in each row explains the condition detected by the controller, while the cause sets out the possibilities associated with it in the reference material. A likely cause is not a confirmed fault: a sensor can report an abnormal reading because of the sensor itself, its connection or the associated circuit. The action column therefore distinguishes user observations from technical work.
Pressure and circulation codes deserve particular attention because they can be confused with each other. Codes involving sensors, configuration, circuit boards or communication require internal components to be checked. In all these cases, there is no need to open the appliance to identify the message, and doing so does not provide a safe user check. The table keeps the faults separate to avoid applying the same remedy to different problems.
| Code | Description | Likely cause | Check or intervention |
|---|---|---|---|
| H00.16 | Abnormal DHW sensor reading due to an open circuit. | Disconnection or signal below the permitted range. | Technical inspection of the sensor and its connection. |
| H00.17 | Abnormal DHW sensor reading due to a short circuit. | Short circuit or signal above the permitted range. | Technical diagnosis; it does not necessarily mean the water is overheating. |
| H00.32 | Open circuit in the outdoor temperature sensor. | Missing connection or reading below range. | Technical inspection of the sensor and its circuit. |
| H00.33 | Short circuit in the outdoor temperature sensor. | Signal above range or short circuit. | Technical inspection of outdoor temperature measurement. |
| H00.34 | The controller cannot detect the expected outdoor sensor. | Sensor not recognised at start-up. | A technician checks installation and configuration. |
| H00.40 | Open circuit in the water pressure sensor. | Disconnection or signal below range. | Read the visible pressure without intervening; a technician checks the sensor. |
| H00.47 | Open circuit in the heat pump circuit temperature sensor. | Missing connection or reading below the permitted range. | Confirm the affected sensor in the manual; technical inspection. |
| H00.48 | Short circuit in the heat pump circuit temperature sensor. | Short circuit or reading above the permitted range. | Confirm applicability to the model; technical inspection. |
| H00.51 | Open circuit in the return temperature sensor. | Disconnection or signal below range. | Technical check of the sensor and its circuit. |
| H00.52 | Short circuit in the return temperature sensor. | Short circuit or signal above range. | Technical diagnosis of the return temperature reading. |
| H00.57 | Open circuit in the upper DHW cylinder sensor. | Missing connection or reading below range. | Technical inspection of the cylinder sensor. |
| H00.58 | Short circuit in the upper DHW cylinder sensor. | Short circuit or reading above range. | Technical inspection; do not replace the sensor without diagnosis. |
| H02.02 | CN1 and CN2 configuration required. | Parameters for the outdoor unit and its output have not been set. | Configuration by a technician using the equipment details. |
| H02.03 | Incorrect CN1 and CN2 configuration. | Values do not match the installed outdoor unit. | Technical correction in the CNF menu. |
| H02.04 | Equipment parameter error. | Corrupted parameters or a persistent control problem. | Settings recovery and control board diagnosis by a technician. |
| H02.05 | CSU and CU mismatch. | Identification or software version discrepancy. | Technical verification of compatibility and software. |
| H02.07 | Active water pressure fault. | Unsuitable pressure or a sensor, connection or wiring problem. | Read the gauge or display; do not fill or drain the system by trial and error. |
| H02.09 | Partial equipment lockout. | BL input open. | Technical investigation of the lockout source; do not bridge contacts. |
| H02.10 | Total equipment lockout. | BL input open. | Technical diagnosis of the external signal and controller. |
| H02.23 | Flow or circulation fault. | Insufficient flow, dirt, air, a stopped circuit or a measurement fault. | Observe symptoms and pressure; hydraulic inspection by a technician. |
| H02.36 | Communication lost with a functional device. | No communication between the main and additional boards. | Technical diagnosis of communication and power supply. |
| H02.37 | Communication lost with a non-critical device. | The additional board stops responding to the main board. | Technical inspection of the accessory and its communication. |
| H02.60 | Function unavailable for this zone. | The selected function is incompatible with the configured zone. | Check the user selection; do not change installation parameters. |
| H06.01 | Outdoor unit fault. | Outdoor fault requiring power supply and communication checks. | External observation without dismantling; technical diagnosis. |
| H06.28 | Platinum BC iR32: communication lost between units. | Indoor-outdoor communication interrupted. | Technical inspection; do not handle cables or connections. |
| H06.06 | Platinum BC iR32: compressor stopped due to high pressure. | High-pressure fault in the refrigerant circuit. | Diagnosis by a suitably qualified technician; do not work on the refrigerant circuit. |
| H06.07 | Platinum BC iR32: compressor stopped due to low pressure. | Low-pressure fault in the refrigerant circuit. | Technical inspection; the code alone does not confirm a leak. |
| H06.36 | Platinum BC iR32: outdoor fan motor fault. | Problem detected in the motor or its operation. | Do not touch the blades or remove guards; technical inspection. |
| E00.00 | Open circuit in the flow temperature sensor. | Disconnection or reading below range. | Technical inspection of supply water temperature measurement. |
| E00.01 | Short circuit in the flow temperature sensor. | Short circuit or reading above range. | Technical inspection of the sensor and its circuit. |
| E02.13 | Lockout requested from outside the controller. | A device connected to BL is keeping that input open. | Identify the source through technical diagnosis without bypassing protection. |
| E02.24 | Shutdown due to insufficient flow. | Circulation does not reach the minimum required by the equipment. | Resolve the cause before carrying out the reset specified in the manual. |
| A02.06 | Water pressure warning. | Pressure condition that may prevent subsequent starts. | Check the reading and manual; arrange inspection if it persists. |
| A02.22 | Circulation system warning. | Fault associated with flow and the hydraulic circuit. | Observe operation; technical inspection of the circuit, filters and pump. |
| A02.55 | Serial number not recognised. | Identification missing, invalid or corrupted in memory. | Technical verification of identification and configuration. |
Pressure and flow are not corrected in the same way
H02.07 and A02.06 point towards water pressure in the heating circuit. H00.40, by contrast, points to the pressure sensor’s measurement circuit. You can read the gauge or the value shown by the controller, but an abnormal reading does not prove there is a water leak. A measurement problem is another possibility, and recognising the difference prevents unnecessary topping up or inappropriate work.
H02.23, A02.22 and E02.24 relate to circulation. Pressure describes the circuit’s pressurised state; flow describes how much water is moving through it. A system can display apparently suitable pressure yet still fail to circulate enough water because of dirt, air, a stopped pump or incorrect measurement. In other words, having pressure does not guarantee having flow, just as a full pipe does not guarantee that water is moving along it.
The reference material does not provide a filling pressure or minimum flow rate that applies to every installation covered here. Those values depend on the model and hydraulic design and must be checked in the relevant documentation. Home checks are limited to reading indicators and observing visible leaks. Do not open hydraulic filters, air vents or filling valves to try possible fixes: they can contain hot, pressurised water and require a controlled intervention.
If E02.24 returns after a reset authorised by the manual, do not keep trying to restart the unit. The shutdown protects the equipment against insufficient circulation, and clearing the warning does not restore water movement. If DHW is also affected, using hot water alone should not be assumed safe: both services may share installation components affected by the same fault.
Sensors report a reading, not always the actual temperature
Many H00 messages, along with E00.00 and E00.01, describe measurement faults. A sensor converts temperature into a signal that the controller can interpret. When an open circuit or short circuit occurs, that signal becomes unreliable. An out-of-range value does not necessarily mean an extreme temperature in the water or outdoor air.
The sensor’s location helps explain the symptom. The flow sensor measures water leaving for the heating system; the return sensor monitors water coming back. Cylinder sensors support DHW control, while the outdoor sensor provides information about ambient conditions. They are not interchangeable simply because they measure temperature, and the code is not a reason to buy a generic sensor without checking the model and diagnosis.
It also matters whether a sensor is not detected or has an abnormal electrical reading. H00.34 means the controller expected to find an outdoor sensor but could not locate it; H00.32 and H00.33 describe conditions in its measurement circuit. That distinction can direct a technician towards installation, configuration or connection issues. For the user, the boundary comes before accessing the wiring, even when the component looks small or easy to replace.
Outdoor unit faults and lockouts need context
H06.01 identifies an outdoor unit fault, but does not, by itself, specify which component has failed. On Platinum BC iR32, H06.28 narrows the issue to lost communication, while H06.36 concerns the fan motor. From a safe position, you can observe whether an object is resting against the grille or whether obvious surface dirt is present. Do not insert tools or hands through the guards, even if the fan appears to have stopped.
H06.06 and H06.07 on that range concern high and low refrigerant circuit pressure. They do not describe the water pressure shown on the heating gauge. This distinction prevents a particularly inappropriate response: adding water does not correct a refrigerant circuit fault. Nor does a low-pressure alarm, without further testing, confirm a refrigerant shortage or a need for recharging.
BL-related messages represent a different situation: the controller receives a lockout condition through an input provided for that purpose. H02.09 describes a partial lockout, H02.10 a total lockout and E02.13 an external lockout request. A connected device may need investigation rather than the heat pump needing replacement. Never try to bypass the lockout by bridging contacts, because that would remove a signal whose purpose has not yet been established.
A restart must not erase the installation settings
A user restart and a factory reset are not equivalent. The former should only follow the procedure allowed by the manual; the latter can remove settings needed for the outdoor unit, zones and accessories to work correctly. With H02.02 or H02.03, CN1 and CN2 must match the installed equipment, not values copied from a similar installation.
H02.04 is particularly easy to misinterpret. The reference material describes restoring settings and, if the problem persists, assessing the main board. That does not make board replacement the first step or a factory reset a harmless home test. With H02.05, the focus is on agreement between CSU, CU and software. Configuration is part of technical diagnosis, not a sequence of trial-and-error checks.
H02.36 and H02.37 indicate lost communication with additional boards, while A02.55 concerns recognition of the serial number. Mention whether the warning appeared after maintenance, a component replacement or a system modification. That timing does not prove who or what caused the fault, but it can prevent replacement of working components when the actual problem is their identification or compatibility.
H02.60 has a different meaning: the selected function is unavailable for that zone. It is reasonable to check which zone is selected on the controller and which uses the manual permits. There is no need to change installer settings to try different combinations. If the function used to be available and has disappeared, keep that information for the inspection, rather than attempting to rebuild the configuration yourself.
An inspection starts with observations, not dismantling
Useful checks are those that do not alter the installation. You can read the pressure, check the selected zone, look for water marks and observe the clearance around the outdoor unit from outside. Cleaning should be limited to accessible surfaces and tasks authorised by the manual. A hydraulic filter is not a removable household filter: opening its housing can release hot, pressurised water.
Before any permitted reset, record the code and the circumstances in which it appeared. It matters whether it occurred during a DHW demand, when heating started or after a modification. If the message returns, the next step is diagnosis, not repeated restart attempts. If water is reaching electrical parts, there is a burning smell or unusually loud abnormal noise, stop using the equipment and avoid touching it; inspection requires qualified personnel.
If contractual cover or an applicable warranty remains in place, checking its terms before authorising work can prevent unnecessary decisions. Opening the equipment does not allow safe diagnosis of sensors, boards or refrigerant issues, and interference can complicate a later assessment. Preserving the equipment’s condition and the warning record is more useful than dismantling it to photograph a supposedly faulty part.
The cost depends on the cause, not the letters on the screen
The available reference material provides no verifiable repair price associated with these codes. Applying a commercial subscription advertised for boilers to a heat pump would also be inappropriate. The same message may lead to a configuration correction, connection checks or component repairs, and the code cannot establish a repair price without knowing the underlying cause and model.
Before accepting a repair, distinguish the diagnostic charge from the proposed work and check whether travel, labour and materials are included. Do not assume the call-out charge will be deducted later. When deciding between repair and replacement, consider age, overall condition, part availability and the extent of the damage. A single warning does not justify replacing the whole system, just as an older unit does not make every repair worthwhile.
The soundest decision comes once the message has been linked to a verified cause and a specific intervention. Until then, the table helps locate the problem and define what can be observed without risk. Baxi heat pump fault messages are a diagnostic tool, not an instruction to replace parts: reading them against the correct model prevents confusion between a protective shutdown, a measurement fault and an actual component failure.
This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.
Ceramic hob6 days agoF error on a Siemens hob: what it means and what to do
Kitchen plate6 days agoF error on a Teka induction hob: causes and solutions
Kitchen plate6 days agoTeka induction hob F4 error: causes and safe checks
Kitchen plate7 days agoError 22 on a Siemens induction hob: what to do
Drying machine7 days agoLG dryer d95 error: causes and safe checks
AEG7 days agoAEG dryer E60 error: what it means and what to check
Ceramic hob6 days agoSiemens ceramic hob E error: causes and safe checks
Bosch6 days agoBosch induction hob E error: causes and what to do
Bosch6 days agoBosch oven E05-32 error: what to check and when to stop
Cata6 days agoCata hob error 03: what it means and how to resolve it
Drying machine7 days agoSiemens dryer E56 error: what you can safely check
Electrolux5 days agoElectrolux oven F102 error: causes and safe troubleshooting