Boiler Sime Error Codes

When your Sime boiler starts showing unusual behaviors, the first thing you should do is check if it’s displaying any error codes on its control panel. These codes are a direct way your boiler tries …

Read more

Error F11 in Sime boiler

How to eliminate F11 error in boiler Sime? Error: F11 Description: Indicates that there is an anomaly due to lack of water circulation. The lack of water circulation is detected whenever the temperature increase read by the …

Read more

Error F10 in Sime boiler

How to eliminate F10 error in boiler Sime? Error: F10 Description: Indicates an anomaly due to low water pressure. The prisoner detects that there are less than 0.5 bars and the boiler stops working. Cause:  Solution: The system …

Read more

Error F09 in Sime boiler

How to eliminate F09 error in boiler Sime? Error: F09 Description: Indicates a problem in the stagnant-open configuration, possibly an anomaly in the X15 card connector wiring. The boiler stops. Cause:  Solution: Request a qualified technician who correctly …

Read more

Error F08 in Sime boiler

How to eliminate F08 error in boiler Sime? Error: F08 Description: Indicates an anomaly in the air pressure with the stopped fan. This occurs when the boiler, while working, detects the air signal but the fan does …

Read more

Error F07 in Sime boiler

How to eliminate F07 error in boiler Sime? Error: F07 Description: Indicates that there is a malfunction of the air transducer (it is open or has a short circuit). The boiler stops. Cause:  Solution: Look for a qualified …

Read more

Error F06 in Sime boiler

How to eliminate F06 error in boiler Sime? Error: F06 Description: Indicates that there are errors or breakdowns in the external probe (if any). If the external probe is open, poorly installed, or has a short circuit, …

Read more

Error F05 in Sime boiler

How to eliminate F05 error in boiler Sime? Error: F05 Description: Indicates an air pressure anomaly below the transducer threshold. If the proper pressure value is not detected after 10 seconds of fan activation, F 05 appears …

Read more

Error F04 in Sime boiler

How to eliminate F04 error in boiler Sime? Error: F04 Description: Flame not detected at the end of a complete starting sequence, due to real flame absence or because the card does not detect it. Also the …

Read more

Error F03 in Sime boiler

How to eliminate F03 error in boiler Sime? Error: F03 Description: Indicates that there are problems in the heating probe (SM). The sensitive part of the heating probe is open or has a short circuit. Cause:  Solution: Look …

Read more

Error F02 in Sime boiler

How to eliminate F02 error in boiler Sime? Error: F02 Description: Health probe problems (SS) when there is. The sensitive part of the health probe is open or has a short circuit. Cause:  Solution: Look for qualified personnel …

Read more

Error F01 in Sime boiler

How to eliminate F01 error in boiler Sime? Error: F01 Description: Blocking due to excess temperature. There is intervention of security thermostat (TS). The boiler does not start and the burner is blocked. Cause:  Solution: Press the Rearme …