Hermann boiler F20 error: causes and safe solutions
A thermal lockout does not identify the faulty part. These checks help you decide what to do safely.

Code F20 or F.20 on a Hermann boiler indicates a temperature-related safety shutdown: the system has activated its overheating protection. It does not prove that a particular part has failed, because incorrect sensor readings or electrical problems can also trigger it. If it returns, do not force the boiler to run: a qualified heating engineer needs to identify the cause.
If you have a problem with your boiler, you can use our free error code finder. It helps you identify errors and find clear, practical guidance on resolving them.
A thermal lockout is not a diagnosis of the fault
On the Hermann MicraCom Condens models covered here, F.20 is described as a safety shutdown associated with the temperature limiter. The boiler stops because it detects a condition that prevents it from continuing to heat normally. That shutdown is a protective response, not an instruction to automatically replace the limiter, pump or electronic control board.
The distinction matters because there are two different scenarios. The temperature may genuinely be excessive, for example if heat is not being carried away properly into the heating circuit, or an incorrect signal may trigger the lockout. From outside, both can produce the same message on the display. The code reports the condition detected, but does not establish which component caused it.
The flow temperature is the temperature of the water leaving for the heating system; the return temperature is that of the water coming back. The electronics use these readings to control operation. If either reading is wrong, the boiler may interpret a thermal condition that does not reflect reality. A casing that feels only warm or cold radiators therefore do not rule out the fault or justify repeated attempts to start the boiler.
There is also no basis for specifying a universal trip temperature for every Hermann boiler. The threshold and protection logic depend on the model and its technical documentation. Using a figure found for another boiler can mislead the diagnosis. The correct reference is always the manual for the specific appliance, rather than simply the brand on the front.
Temperature sensors and ignition faults explain some F20 lockouts
The technical information available for these ranges identifies a faulty flow sensor, a defective return sensor, an incorrect earth connection and electrical discharge involving the ignition lead, connector or electrode as possible causes. These are separate possibilities requiring professional testing. There is insufficient evidence to describe any one of them as the most common cause across all installations.
Temperature sensors measure temperature, while the limiter provides protection against an unsafe thermal condition. Although some descriptions use the terms interchangeably, a sensor and a limiter are different. Confusing them can lead to buying a replacement that does not address the fault, or does not even match the configuration of that boiler.
A faulty earth connection or unwanted discharge from the ignition system cannot be fixed by cleaning the outside or changing room thermostat settings. Checking them involves internal electrical components and requires appropriate equipment and expertise. Users should not remove the casing, reposition connectors or test components: electrical checks require an engineer, even when the boiler appears to be switched off.
An F20 appearing during start-up can be a useful observation, but it does not prove that the electrode is responsible. Equally, an error appearing after several minutes does not automatically identify a sensor fault. The sequence helps guide testing; it cannot replace it. Before buying parts, you need a diagnosis supported by measurements, rather than a quick association between a code and a replacement component.
Water circulation and flue problems need proper context
A boiler can overheat if it generates heat but the water does not carry that heat away effectively. A seized pump, air in the circuit or restricted circulation are possibilities an engineer may consider when investigating genuine overheating. However, these causes are also associated with other specific warnings. F20 should not be treated as confirmation of pump failure or a shortage of water.
One useful example is a boiler that heats up quickly while the radiators receive very little heat. That behaviour provides information about a possible circulation problem, but cannot distinguish externally between a blockage, air, poor pumping or an incorrect reading. Cold radiators do not always indicate a fault either: demand and controls also matter. The useful clue is the relationship between operation and lockout.
Some descriptions link F20 to flue problems. That possibility does not justify attributing every thermal lockout to a blocked flue. Micraplus Condens documentation also includes F25, a separate warning relating to flue gas temperature. Water, measurement and combustion problems must be distinguished through a model-specific inspection, without mixing up the meanings of different codes.
It is not safe to dismantle the flue, insert objects to clean it or try to free the pump through its front screw. Nor should the circuit be opened to release water or air as an experiment when F20 appears. Such work can involve hot water, pressure, electricity or combustion products. Internal and flue inspections are outside the scope of household checks.
What you can observe without opening the boiler
The most useful checks start with the display and accessible controls. Record the code exactly as shown, the model, and whether the lockout occurred when heating was requested, a hot tap was opened or there was no obvious demand. A photograph preserves details that may disappear when the appliance is switched off. This operating information is more helpful than several unrecorded attempts to restart it.
You can also read the pressure gauge or on-screen pressure without operating any valves. Some general guidance mentions 1 to 1.5 bar when cold, but this must not become a universal target for every Hermann installation. Check the applicable value in the model’s manual. An apparently normal pressure does not rule out circulation problems or incorrect temperature measurements.
If the reading falls outside the manufacturer’s stated range, record it and pass it on. F20 is not an instruction to refill the circuit, and opening the filling valve without identifying the cause can introduce a pressure problem. Here, the safe limit is to observe, not adjust the pressure. Repeated pressure loss or a reading that changes abnormally needs professional assessment.
From outside, without touching hot surfaces, you can look for drips, moisture beneath the boiler or fresh marks around visible connections. Do not loosen joints to find a leak or remove panels to trace it. If water appears near electrical components, avoid handling the appliance. A visible leak changes the priority: its cause needs checking before you attempt to restore operation.
Resetting is not the same as repairing
A reset may clear the lockout and allow another attempt to operate, but it cannot repair a defective sensor, an electrical connection or inadequate circulation. A display returning to normal therefore does not prove a repair. Subsequent behaviour and the cause of the first warning still matter, particularly if the error has appeared before.
A user-accessible reset should only be considered when the manual for that boiler permits it and there are no additional abnormal signs. Follow the manufacturer’s procedure rather than inventing button combinations or waiting times. There is no single waiting period that applies to every Hermann. If the appliance remains hot or behaves unusually, do not force a restart.
If F20 returns after a permitted reset, stop trying and arrange a technical inspection. Repeated resets provide no diagnosis and restart the process that is triggering the protection. Running the boiler intermittently to obtain hot water is not an appropriate workaround either. A recurring thermal lockout needs investigation, even if the appliance seems normal between shutdowns.
If you notice a gas smell, burning smell, smoke or a substantial leak, do not reset the boiler. If you smell gas, avoid operating electrical switches or creating flames, and follow the gas emergency service’s instructions from a safe location. These signs cannot simply be explained away by F20: they require a different response from resetting and attention from the appropriate services.
Related codes help distinguish different problems
The table distinguishes F20 from other sensor, water and temperature warnings included in the available Hermann Micraplus Condens information. It helps interpret a code appearing before or after the lockout, rather than transferring every meaning to all Hermann boilers. In each case, the exact appliance range and its documentation take priority.
| Code | Description | Cause | Scope of inspection |
|---|---|---|---|
| F00 | Flow temperature sensor fault or interruption. | Defective sensor, loose connector or interrupted wiring. | Engineer diagnosis of the sensor and connections. |
| F01 | Return temperature sensor interruption. | Defective sensor, loose connection or interrupted wiring. | Professional inspection of the measurement circuit. |
| F10 | Flow temperature sensor short circuit. | Faulty sensor or short circuit in its wiring. | Professional internal electrical testing. |
| F11 | Return temperature sensor short circuit. | Defective sensor or short circuit in the wiring. | Professional internal electrical testing. |
| F20 / F.20 | Overtemperature safety shutdown. | Defective flow or return sensors, incorrect earth connection or ignition system discharge; genuine overheating must be investigated. | Observe the display and pressure; an engineer diagnoses the cause. |
| F22 | Safety shutdown due to insufficient water. | Insufficient water, pressure sensor fault or wiring and connection problems. | Read the pressure without working on the circuit. |
| F23 | Excessive difference between flow and return temperatures. | Blocked or underperforming pump, air or reversed sensor connections. | Professional circulation and sensor checks. |
| F24 | Temperature rising too quickly. | Pumping problems, air, insufficient pressure or gravity brake problems. | Professional diagnosis of the hydraulic circuit. |
| F25 | Safety shutdown associated with high flue gas temperature. | Loose connection or interrupted wiring to the flue gas temperature limiter. | Technical inspection of the protection system and flue. |
| F75 | Fault relating to pressure detection. | Pressure sensor, pump, insufficient water or air in the appliance. | Professional checks; the code alone does not identify a part. |
| F83 | Abnormal temperature change detected by the sensors. | Insufficient water or pressure, or inadequate sensor contact. | Professional checks of circuit water and sensors. |
A second code does not necessarily mean there are two independent faults. The same circulation difficulty can trigger different protective conditions, while an incorrect electrical signal may affect several readings. Keeping a complete record of the warning sequence is useful, but collecting codes does not establish the cause without the relevant checks.
It is particularly important not to confuse F20 with F22. Insufficient water is the specific meaning of F22 in the range described; it should not be inferred merely because the boiler has stopped. F23 and F24 likewise provide different thermal information. Keeping these distinctions clear prevents every lockout being treated with the same action and helps avoid refilling or bleeding without diagnosis.
The exact model matters more than similarities between brands
The main explanation of F.20 is based on the Hermann MicraCom Condens 24-AS/1 and 28-AS/1. The comparative information about other codes comes from Micraplus Condens. Although both families belong to the same brand and share operating principles, their components, reset procedures and complete fault tables should not be assumed to be interchangeable.
You can find the model name in the documentation supplied with the boiler or on an externally accessible label. Do not remove the casing to look for it. An invoice, maintenance record or photograph of the identification label may help establish the version. The model and appliance reference are more useful in preparing a diagnosis than a general description of its appearance.
Hermann shares a corporate group with Saunier Duval and Vaillant, but that relationship does not make every code universal. Even where letters and numbers match, prescribed checks or equipment configurations may differ. A procedure found for another brand must not replace Hermann’s model-specific instructions, particularly when it involves service settings or dismantling.
It is also important to distinguish the user manual from installation and maintenance documentation. Detailed F20 information may appear in material intended for professionals, with tests that are not suitable for the owner. An operation being described in a technical manual does not make it a household task. Access to information does not remove the risks or the need for appropriate qualifications.
Buying a sensor before diagnosis may be unnecessary
The code does not provide a replacement part number or determine what needs changing. A flow sensor, return sensor and ignition system problem require different solutions, and compatibility depends on the appliance version. Buying by visual similarity or a broad sales description may leave the lockout unchanged. The decision should follow a confirmed cause, not an assumption.
There is no basis for declaring the electronic control board faulty simply because F20 returns after a reset. Temperature readings, their connections and the other model-specific causes need to be distinguished first. Replacing a board without those checks can increase the cost without solving the problem. Recurrence indicates that the problem remains present, not where it is located.
There is no verified price available that would support a reliable cost estimate for this fault. The amount depends on the cause, the required part and the terms of the work. Before authorising a repair, establish whether diagnosis and call-out charges are separate and whether they are deducted from the repair bill. The useful comparison is an itemised quotation, not a generic figure attached to the code.
If the boiler has current cover, check its terms before arranging work or buying components. It should not be assumed that opening an appliance automatically removes every right, but interference can complicate damage assessment and claims. Keeping photographs, warnings and maintenance records helps explain the case without altering the boiler. The prudent approach is to document before anyone intervenes.
Restoring service depends on correcting the cause
An isolated F20 does not, by itself, justify replacing the whole boiler, just as an older appliance should not be repaired at any cost. The decision depends on the affected component, its availability, the overall condition and the fault history. If a substantial repair is proposed, its scope should be compared with full replacement. The deciding factor is the actual condition of the appliance, not the code alone.
For a useful inspection, explain when the fault began, whether there has been recent work on the installation, what pressure you observed and whether there are noises or visible leaks. These details help reconstruct its behaviour without triggering the lockout again. You do not need to keep starting the boiler to demonstrate the fault: a record of symptoms is enough to begin a professional assessment.
Safe recovery means more than making F20 disappear from the display. The reason the protection activated must be identified and corrected, followed by the appropriate model-specific operating checks. While the lockout keeps returning, continued use through repeated resets is not appropriate. The boundary is clear: external observations and user controls are acceptable; internal work is for professionals.
This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.
Balay6 days agoC20 error on a Balay washing machine: causes and safe fix
Boiler5 days agoBuderus boiler 6A error: what it means and what to do
Boiler5 days agoImmergas boiler error 01: what to do if it will not ignite
Boiler5 days agoWolf boiler E04 error: what it means and what to do
Boiler5 days agoAP error on a Domusa boiler: what it means and what to do
Boiler6 days agoManaut boiler error 01: causes and safe checks
Boiler6 days agoVaillant boiler F75 error: what it means and what to do
Baxi5 days agoBaxi boiler E01 error: what it means and what to do
Beretta5 days agoBeretta boiler A01 error: what it means and what to do
Boiler4 days agoChaffoteaux boiler error 108: causes and solutions
Boiler6 days agoTifell boiler error 13: causes and safe troubleshooting
Baxi6 days agoBaxi boiler E133 error: what it means and what to do