Error 11 on an Immergas boiler: meaning and safe action
A flue warning does not prove a part has failed. Know what you can observe and what needs professional inspection.

Code 11 on an Immergas Eolo Star 23 kW indicates a flue pressure switch fault: the boiler cannot confirm the conditions needed to discharge combustion gases correctly and stops operating for safety. Possible causes include a blockage, the fan, the monitoring system or the duct installation. The code alone does not identify a failed component, and repeated resets are not a solution; inspecting the combustion system requires a qualified, authorised engineer.
If you have a problem with your boiler, you can use our free error code finder. It can help you identify and resolve errors easily and effectively.
The warning identifies a safety condition, not a specific part
On the Eolo Star 23 kW, the flue pressure switch helps check that the air and flue system is working. Although its name might suggest that it measures smoke directly, it operates through pressure differences associated with that circuit. If the expected response is missing, the control system prevents normal operation. A fault indication does not prove failure of the pressure switch itself: it may be correctly detecting a problem elsewhere.
This distinction changes the approach to repair. Replacing the detector without checking airflow would be like replacing an alarm because it sounded, without finding out what triggered it. A fan that cannot move enough air, a blocked duct or an unsuitable installation can produce the same warning. Diagnosis must establish which operating condition is missing before deciding whether cleaning, installation changes or component replacement is necessary.
The full model designation matters too. Eolo Star, Eolo Mini, Eolo Eco and the various Victrix families should not be treated as one boiler with identical codes. The explanation of code 11 here focuses on the Eolo Star 23 kW. For any other version, the exact model identification and its documentation determine the meaning of the message, how the shutdown behaves and which checks are appropriate.
Both the air intake and flue can cause the problem
The Eolo Star is a room-sealed boiler: its combustion chamber is separated from the indoor environment and receives the air it needs from outside through ducts. The resulting gases also discharge outdoors, assisted by the fan system. This separation does not remove the need to check the flue; it depends on the assembly maintaining correct sealing and airflow. Opening the casing or loosening joints to make the boiler run changes those very conditions.
The installation may use a concentric flue, with air and exhaust passages incorporated into one assembly, or separate ducts. Configurations described for this family include 80/125 mm and 80/80 mm components, respectively. These dimensions relate to specific configurations, not instructions for adapting any outlet or permission to replace pipes with others that look equivalent. Compatibility depends on the model, the kit and the permitted layout.
A problem can affect either the intake or the exhaust. Seeing some vapour leaving the terminal, or hearing the fan turning, is therefore not enough. Neither observation alone confirms correct operation under all conditions. A professional assessment needs to consider the entire air and flue route, including its joints and configuration, rather than only the section visible from the home.
One code can have several causes
Code 11 can result from a blocked terminal or duct, a seized or faulty fan, an installation deficiency or a problem with the system that confirms flue operation. The small tubes and connections associated with the pressure switch are also part of the engineer’s diagnosis. The table separates these possibilities without turning them into DIY repair instructions: each requires a cause assessment, not parts replacement based solely on the display number.
| Code | Description | Possible cause | Appropriate check or remedy |
|---|---|---|---|
| 11, Eolo Star 23 kW | Flue pressure switch fault. | Blockage in the air intake or combustion gas exhaust. | The user may observe the terminal from a safe location. Inspection and clearance of the circuit require a qualified, authorised engineer. |
| 11, Eolo Star 23 kW | The required flue operating conditions are not confirmed. | Fan seized, damaged or not operating correctly. | Professional diagnosis of the fan and its operating conditions before deciding on replacement. |
| 11, Eolo Star 23 kW | Incorrect response from the flue monitoring system. | Fault involving the pressure switch or associated connections. | Professional inspection of the monitoring system. Never bypass the device. |
| 11, Eolo Star 23 kW | Incorrect operation of the air and flue circuit. | Unsuitable layout, assembly or sealing. | Check the installation against the model specifications and have an authorised professional correct it. |
When the warning appears can help guide the inspection, but it does not provide a complete diagnosis. Useful information includes whether it started after work on the building exterior, after work on the ducts or during windy weather. It also helps to know whether it occurs during hot water or heating demand. These details help reconstruct the circumstances of the fault without requiring the user to open the appliance or trigger further starts to reproduce it.
Silence from the fan is not enough to condemn it, and an apparently normal sound does not prove that it is working properly. The sequence may stop before the fan is called to run, or its airflow may be insufficient for the required conditions. Likewise, a persistent code does not automatically confirm a circuit board fault. Blaming the most expensive component without checking the rest is an unsupported diagnostic leap that can lead to unnecessary expense.
Home checks stop before any dismantling
The most useful contribution from the user is to preserve reliable information. A photograph of the code and another of the appliance identification, if accessible without dismantling anything, can prevent confusion between similar models. It also helps to note whether the warning is continuous or intermittent and what the boiler was doing when it appeared. This observation without intervention contributes more to diagnosis than repeatedly clearing the message or changing settings to make it disappear.
The outside terminal should only be viewed from a stable, accessible position, without leaning out dangerously or using a ladder to reach it. If a bag, vegetation, ice or another object appears to be covering it, report this to the engineer. Do not insert tools, remove guards, chip away ice or apply heat. A visible blockage does not make intervention safe: the terminal is part of the combustion system and could be damaged or displaced.
Ventilation grilles in the home must not be covered, but uncovering them does not prove that code 11 has been resolved. A room-sealed boiler receives combustion air through its dedicated circuit. Confusing these two routes can lead to a fault being considered fixed when it remains present. Do not disconnect pressure switch tubes, touch electrical connections or dismantle the fan; these tasks are outside the scope of home checks, even if the appliance appears to be switched off.
If the warning persists or returns, stop demand using the user controls specified in the manual and arrange an inspection by an authorised engineer. If there is also a carbon monoxide alarm, an unusual smell of combustion gases or symptoms such as dizziness and headache, the priority changes: leave the property and seek help from a safe location. If you smell gas, do not operate electrical switches or attempt to restart the boiler.
A reset does not prove that the flue is working correctly
On the Eolo Star 23 kW, the flue pressure switch warning can clear automatically when the required operating conditions return. It should not be confused with a lockout that always requires the reset button. The instructions for the exact appliance version take precedence. In any case, resetting does not remove a blockage, restore a deteriorated fan or correct an improperly assembled joint or duct layout.
Hot water returning does not, by itself, establish that the boiler has been repaired. An intermittent cause may stop showing itself for a while and return under another demand or different outdoor conditions. If code 11 recurs, it should not be accepted as a normal characteristic of the appliance. The important point is not how many resets it allows, but why recovery is repeatedly needed.
Descriptions of the display colour are inconsistent: some associate code 11 with orange and others with red. That disagreement means colour cannot serve as a general measure of seriousness or a reliable way to identify the fault. The displayed code, the model and its instructions should take precedence. A change in display colour does not make continued use acceptable, nor does it replace model-specific interpretation of the warning.
The number must be read alongside the model
Code 11 on the Eolo Star should not be confused with low heating system pressure or an ignition lockout. Although any of these can leave a home without hot water, they describe different conditions. Opening the filling valve to try to resolve a flue fault affects another circuit and does not remove the cause. Water pressure and flue operation checks are separate matters.
The comparison also helps prevent codes being transferred between different ranges from the same manufacturer. The Victrix Omnia has specific warnings relating to the fan and air intake, but their numbers do not replace code 11 on an Eolo Star. The following table brings together codes relevant to this common confusion. The causes are indicative, not parts prescriptions: a warning describes a condition, not necessarily the responsible component.
| Code | Reference model or range | Description | Cause or area for inspection |
|---|---|---|---|
| 01 | Eolo Star; confirm the version. | Ignition failure lockout. | Ignition does not complete correctly; diagnosis is needed if it persists. |
| 10 | Eolo Star; confirm the version. | Insufficient system pressure. | Water circuit pressure conditions or their detection; not equivalent to a flue fault. |
| 11 | Eolo Star 23 kW. | Flue pressure switch fault. | Exhaust, air intake, fan, installation or monitoring system. |
| 27 | Eolo; confirm the model and version. | Insufficient circulation. | Heating water circulation; does not identify a blocked flue duct. |
| 16 | Victrix Omnia. | Fan fault. | Fan operation and control; professional inspection required. |
| 92 | Victrix Omnia. | Fan speed correction limit reached. | Fan regulation and the operating conditions of the assembly. |
| 96 | Victrix Omnia. | Air intake ducts obstructed. | Possible air intake blockage; professional verification required. |
Another source of confusion is the illustrations in manuals. In the Victrix Tera 28 1 documentation, for example, number 11 identifies a flame presence symbol in a control panel diagram. That key number does not mean the text is describing fault code 11. It is important to distinguish diagram references from messages that actually appear on the display, especially when reading a single page from a manual.
An inexpensive part can become an unnecessary repair
Buying a pressure switch because the message mentions it is premature. If the device is correctly detecting poor flue operation, replacing it will not solve the cause. Parts intended for the Eolo Star, Eolo Eco or Eolo Zeus are not interchangeable merely because they share a brand or look similar. Before purchasing, diagnosis and compatibility need confirmation from the person carrying out the work, rather than just a matching product name.
The code does not establish the cost either. Work on a duct is different in scope from replacing a fan, correcting an installation or repairing the monitoring system. Prices advertised for parts for other variants, particularly refurbished ones, do not represent the final cost of this fault. Without a specific assessment, the honest distinction is between a spare part and a complete repair, which may include diagnosis, travel, labour and subsequent checks.
Before agreeing to work, the quotation should clarify whether diagnosis or travel is charged separately, whether those charges are credited against the repair and which checks are included. Do not assume that every business applies the same terms. The cause found should also be stated: a proposal that merely says replace pressure switch leaves unanswered what justifies the replacement and how a flue deficiency has been ruled out.
Choosing between repair and replacement requires more than knowing the appliance’s age. Overall condition, the availability of compatible parts, the fault history and any need to correct the installation all matter. An isolated code 11 is not enough to declare the boiler beyond use; nor does it make every repair worthwhile. The useful comparison is between a repair with an identified cause and defined scope, and a replacement option that accounts for the installation as a whole.
Recovery should include an identified cause
A complete intervention does not end when the number disappears from the display. The engineer needs to check that the air and flue circuit, fan and monitoring system operate under the conditions specified for that appliance. If an installation has been corrected or a part replaced, the result also needs verification. The aim is to restore safe operation, not achieve a single successful ignition while leaving the origin of the warning unexplained.
For the user, the most valuable information at the end is straightforward: what caused the fault, what was corrected and whether anything remains outstanding. Understanding internal measurements is not necessary to request a clear explanation. If the fault does not occur during the visit, the recorded circumstances and photographs can help, but its temporary absence does not justify replacing parts at random. Intermittent faults also need a reasoned diagnosis.
On an Eolo Star 23 kW, code 11 directs attention to flue monitoring; it does not confirm a lack of gas, low water pressure or a broken pressure switch. The user’s role is to identify the model, observe without dismantling and avoid further attempts if the warning persists. Beyond that, inspection of the combustion system belongs to a qualified, authorised engineer. Getting the boiler working again matters; establishing why it stopped is what allows the repair to be considered complete.
This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.
Balay6 days agoC20 error on a Balay washing machine: causes and safe fix
Boiler5 days agoBuderus boiler 6A error: what it means and what to do
Boiler5 days agoImmergas boiler error 01: what to do if it will not ignite
Boiler5 days agoWolf boiler E04 error: what it means and what to do
Boiler6 days agoAP error on a Domusa boiler: what it means and what to do
Boiler6 days agoVaillant boiler F75 error: what it means and what to do
Baxi6 days agoBaxi boiler E01 error: what it means and what to do
Boiler4 days agoChaffoteaux boiler error 108: causes and solutions
Boiler6 days agoManaut boiler error 01: causes and safe checks
Beretta5 days agoBeretta boiler A01 error: what it means and what to do
Boiler6 days agoTifell boiler error 13: causes and safe troubleshooting
Baxi6 days agoBaxi boiler E133 error: what it means and what to do