Boiler
Manaut boiler E04 error: what it means and what to do
Pressure helps narrow down the fault, but it is not the whole story. These signs help you decide without opening the boiler.

An E04 code on a Manaut boiler usually indicates insufficient pressure or poor circulation in the central heating circuit. On the Myto Condens, it may appear as Er 04 and, on certain remote controls, as 04E; E04 is also used on the Midas Eco. The first check is to read the pressure gauge when the system is cold: 1 to 1.5 bar is a common reference range, although the instructions for the specific model take priority. If the pressure is correct and the warning remains, the boiler needs professional diagnosis, not simply more water.
If you have a problem with your boiler, you can use our free error code finder. It can help you identify errors and understand how to resolve them easily and effectively.
Pressure and circulation are two different problems
A system can contain water without moving it properly. Pressure describes the condition of the circuit; circulation carries heat from the boiler to the radiators. The warning covers related situations, but does not identify a specific part. Reading the number on the display as an instruction to replace the pump can therefore lead to an unnecessary repair.
With insufficient pressure, the boiler may lock out to avoid operating under unsuitable conditions. With apparently normal pressure, the problem may involve the pump, a restriction, trapped air or the pressure detection system. These possibilities require different tests. The gauge provides an initial clue, but cannot establish on its own that the whole circuit is working correctly.
The model matters as much as the code. The Myto Condens and Midas Eco share some fault descriptions, but that does not make every version equivalent. Identify the appliance from its paperwork or an accessible label, without removing the casing. It is also important to record the exact letters and numbers on the display rather than treating every warning containing 04 as identical.
The pressure gauge is best read with the system cold
The usual reference range of 1 to 1.5 bar applies to a cold pressure reading. After the heating has been running, the water expands and pressure may rise. Comparing a hot reading with one taken hours later can create the impression of a leak that does not exist. To identify a trend, readings should be taken under similar conditions and in accordance with the appliance instructions.
A needle clearly below the range specified for the model supports the possibility of insufficient pressure. However, it does not explain why the pressure has fallen or whether restoring it will be enough. There is no single lockout threshold that can safely be applied to every Manaut boiler without checking: the setting depends on the range and its detection system.
If the gauge shows normal pressure while E04 remains, adding water may raise the pressure unnecessarily without resolving the fault. If the reading is already excessive, improvising a way to drain the circuit is not appropriate either. Home checks stop at observation and recording; filling, draining or working on pressurised water should be left to an appropriately qualified professional in this context.
The useful clues are outside the casing
Without dismantling anything, you can look for water on the floor, dampness below the boiler or marks around accessible radiator connections and pipe joints. Keep this to a visual inspection, without loosening fittings or touching hot areas. A photograph helps preserve the detail, particularly if the dampness later disappears. The aim is to identify visible signs of leakage, not to stop it through improvised adjustments.
It is also useful to check whether the home has a mains water interruption and observe the accessible main stop valve, without forcing it or changing unfamiliar valves beneath the boiler. Central heating is a sealed circuit: water flowing from the taps does not prove that the heating system is holding its pressure, and a mains interruption does not automatically explain a pressure drop in that circuit.
Behaviour before the lockout provides context. Radiators that barely warmed up, water noises or steadily declining pressure tell a different story from a warning appearing suddenly after work on the system. These details can be recorded without provoking further starts. There is no need to reproduce the fault repeatedly: the history of the symptom is often more useful than a series of resets.
Pressure that keeps falling needs an explanation
If pressure is restored after work on the system and then falls again, the problem has not been resolved simply because the code disappeared for a few hours. There may be a leak, discharge through a safety component or an expansion vessel problem. Recurrence is the central clue: restoring pressure is not the same as repairing whatever is causing it to fall.
The expansion vessel absorbs changes in water volume as it heats up. If it is not performing properly, there may be substantial pressure swings between hot operation and cold rest. That pattern helps guide an engineer, but it is not enough to condemn the component. Assessing its condition requires professional checks on the circuit, not operating valves or connections based on a generic description.
The absence of a puddle does not rule out a leak either: parts of the installation may be hidden, or water may leave through a route that cannot be seen from the boiler. Recording pressure, timing and the approximate operating temperature helps distinguish a real drop from an unsuitable comparison. Where pressure falls repeatedly, the priority is to locate the source rather than treating repeated top-ups as routine maintenance.
Normal pressure changes the direction of diagnosis
When the reading remains within the appropriate range but the warning continues, circulation and detection become more important. A pump that is not moving water, a restriction in the circuit or a pressure device reporting incorrectly may produce a related lockout. The priority shifts from the gauge reading to checking how water circulates and is detected.
A professional can distinguish these causes using the checks specified for the model. Users should not attempt to free the pump, access internal filters, disconnect sensors or bypass safety devices. Even a task that appears mechanical may involve electricity, hot surfaces or pressurised water. The casing marks the boundary of the household checks described here.
Stable pressure does not prove that the pump is healthy, and E04 does not prove that it has failed. Nor does it justify blaming the electronic control board through a rushed process of elimination. Before components are replaced, testing should connect the symptom to its cause. That approach avoids trial-and-error parts replacement, which can increase the bill without resolving the lockout.
A reset does not repair the underlying cause
The reset button or control can clear certain lockouts, but its operation varies by model. It should only be used as described in the manual, without transferring button-hold times from one Manaut boiler to another. For a pressure or circulation warning, resetting does not restore water, remove a restriction or repair a pump that has stopped working.
If the code returns immediately after the reset allowed by the instructions, repeating it provides little useful information. It is better to keep the gauge reading and record when the lockout occurs. A warning that appears on a heating demand does not provide exactly the same context as one present as soon as the control panel starts. The timing of the warning helps guide inspection without touching internal components.
A warning disappearing briefly does not prove that the appliance has returned to stable operation either. If it comes back, the cause still needs explaining. Do not make repeated attempts to force a start or disable protective devices. If there are leaks near electrical components, a smell of gas or signs of abnormal combustion, do not continue testing: follow the relevant safety instructions and seek appropriately qualified assistance.
The letters in the code prevent confusion between faults
Warnings with nearby numbers do not mean the same thing. Some descriptions also change between the boiler display and a remote control, while others depend on the boiler family. The following table distinguishes the warning discussed here from other lockouts that may be confused with it. It is model-specific guidance, not a universal catalogue for every Manaut appliance.
| Code | Description | Cause or condition to investigate | Model and response |
|---|---|---|---|
| Er 04 | Insufficient pressure or poor water circulation. | Low pressure, a circulation problem or a detection issue. | Myto Condens. Read the gauge when cold; persistent warnings require qualified diagnosis. |
| 04E | Insufficient water or circulation warning. | Conditions in the central heating circuit that prevent normal operation. | Listed for Myto Condens and Midas Eco; confirm its presentation in the appliance or controller manual. |
| E04 | Insufficient system pressure or lack of pump circulation. | Pressure, water detection, the pump or circuit restrictions. | Midas Eco 24E and 28E. Visual checks; professional inspection if the cause remains unresolved. |
| Er 01 / E01 | Ignition failure lockout. | No flame, or problems with flame detection and the ignition system. | Depending on the Myto Condens or Midas Eco display format. Not a low-pressure warning; professional intervention if persistent. |
| Er 02 / E02 | Safety thermostat activation. | Overheating, possibly poor circulation or a safety device fault. | Model-dependent. Requires inspection if it returns. |
| Er 13 | Excessive difference between flow and return temperatures. | A temperature imbalance that may be linked to insufficient circulation. | Myto Condens. Professional diagnosis of the circuit. |
| Er 14 / E14 | Warning related to circulation or primary circuit temperature. | The precise triggering condition depends on the model. | Myto Condens and Midas Eco have specific descriptions. Do not transfer thresholds between ranges. |
| Er 05 | Fan control fault. | A problem with fan operation or monitoring. | Myto Condens. Qualified inspection, without interfering with the flue system. |
| E05 / 05E | Flue pressure switch fault. | A problem monitoring flue operation, the fan or associated components. | Midas Eco 24E and 28E. Not equivalent to a water pressure warning. |
The distinction involving 05 is particularly important: fan control on the Myto Condens and the flue pressure switch on the Midas Eco should not be reduced to an identical explanation. Likewise, E01 is not a pressure warning on these ranges. Mixing up these interpretations can lead to interference with the wrong circuit or delay a necessary inspection.
The connection between Manaut and Biasi does not make every table for the other brand directly applicable either. A shared platform does not guarantee an identical warning format, electronic system or installed component. Fault interpretation depends on the exact appliance version; selecting a replacement part also requires confirmation of technical compatibility.
The lockout can also leave the home without hot water
Although E04 relates to the central heating circuit, a combination boiler may need that circuit to transfer heat to domestic hot water. A lack of hot water therefore does not automatically point to a separate fault. The lockout may prevent both services from operating. Heating and domestic hot water are different functions, but they share components and operating requirements within the appliance.
Switching to summer mode does not establish that continued use is safe or necessarily avoid the problem. If the fault affects internal circulation or keeps a safety lockout active, changing the demand does not correct the cause. The test is not whether a tap becomes warm at some point, but whether the boiler operates without warnings and with normal pressure and circulation conditions.
Once an engineer has restored those conditions and the appliance is operating in accordance with its manual, the performance of both services can be assessed. Until then, do not force repeated starts to obtain hot water. Keep the earlier observations too: a warning that appears only with a particular demand is useful diagnostic information, not permission to use the other service indefinitely.
The cost depends on diagnosis, not the display number
The same warning may involve a pressure issue, a system leak, a detection problem or a circulation fault. There is therefore no single repair price for E04. To compare proposals, they need to describe the confirmed cause and scope of the work rather than quoting for a pump simply because that code is displayed.
The advertised price of a part alone is not the final cost of repairing the boiler. Travel, diagnosis, labour, materials and subsequent checks may all be involved. Before agreeing to a visit, establish whether diagnosis is charged separately and whether that charge is deducted if the repair goes ahead. A written total price allows meaningful comparisons without confusing a replacement part with a completed repair.
The choice between repair and replacement needs that diagnosis alongside an assessment of overall condition, previous faults and parts availability. E04 alone does not justify replacing a boiler. Nor is buying a pump because it looks similar or shares the brand a sound approach: versions may differ. Replacement only makes sense with the fault and compatibility confirmed by the professional carrying out the work.
A reading and a history are worth more than repeated resets
The most useful information for an inspection fits into a short description: full model, exact displayed code, cold pressure and the circumstances of the lockout. A photograph of the display and another of the gauge prevent transcription errors. Recent work or pressure changes should also be recorded. Documenting before resetting preserves clues that may temporarily disappear from the panel.
With a low reading, the professional needs to establish why pressure is missing and how to restore suitable circuit conditions. With a normal reading, circulation and detection need investigation. If there are pressure swings or recurring losses, diagnosis should include the installation, not just the boiler interior. This distinction helps focus the inspection without presenting a hypothesis as an already proven fault.
The user’s role ends with visible checks, consulting the manual and using controls as intended by the manufacturer. Opening the boiler, working on the pump, repairing internal leaks or interfering with circuits belongs to an appropriately qualified engineer. With a persistent E04 warning, the goal is not to erase the message: it is to restore stable and safe operation with the cause identified.
This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.
Balay5 days agoC20 error on a Balay washing machine: causes and safe fix
Boiler4 days agoWolf boiler E04 error: what it means and what to do
Boiler4 days agoImmergas boiler error 01: what to do if it will not ignite
Balay6 days agoBalay ceramic hob: what the H error means and what to do
Boiler5 days agoTifell boiler error 13: causes and safe troubleshooting
Boiler4 days agoBuderus boiler 6A error: what it means and what to do
Ceramic hob6 days agoBalay ceramic hob: what the reversed 9 and 3 mean
Boiler5 days agoVaillant boiler F75 error: what it means and what to do
Boiler4 days agoAP error on a Domusa boiler: what it means and what to do
Dishwasher5 days agoError 15 on a Balay dishwasher: causes and safe solution
Baxi5 days agoBaxi boiler E133 error: what it means and what to do
Boiler5 days agoManaut boiler error 01: causes and safe checks