Ariston heat pump fault codes: Nimbus and Nuos explained

Nimbus and Nuos fault tables, generation differences and clear limits for safe checks before a professional diagnosis.

Published

on

Códigos de avería en aerotermia Ariston: Nimbus y Nuos

A code on an Ariston heat pump identifies a fault or a protective response, but it does not always identify a failed part. On Nimbus systems, 923 indicates a pressure problem in the heating circuit; 937 concerns water circulation, while 931 indicates an inverter fault that needs further information. Before resetting, identify the model and refrigerant: some meanings change between R32 and R410A. Nuos hot water heat pumps use a separate table.

If you have a problem with your heat pump, you can use our free error code finder. It helps you identify errors and find straightforward, effective ways to resolve them.

The equipment label determines which table applies

Identification starts with the rating plate, which should be checked without dismantling the appliance. Note the full model name, reference and refrigerant. The distinction between R32 and R410A separates two Nimbus generations, although it is not enough on its own: whether the unit is a Plus, Pocket or Compact and its specific documentation version also matter.

Copy the entire code, including any letters. Codes 923, 2P8 and 9E28 are not interchangeable, even though all three may concern pressure: the first two relate to the water circuit, while the third is an outdoor unit high-pressure protection. Confusing water and refrigerant leads to the wrong checks and, sometimes, unnecessary work.

The tables below distinguish the applications identified in the available information. Where Nimbus R32/R410A appears, the description is recorded for both generations, but the installed unit’s manual remains the definitive reference. Instructions for an Ariston boiler or a Chaffoteaux appliance must not be transferred automatically: sharing a manufacturer or platform does not make their codes universal.

Nimbus sensors, pressure and water circulation

Nimbus controls monitor temperatures, water movement, storage and communication between modules. A temperature sensor measures heat; the circulating pump moves water around the system. When a reading is invalid, the system may stop a particular function or halt production to avoid operating without a reliable measurement.

The cause column distinguishes the detected problem from its possible origins. A sensor fault, for example, may involve the sensor itself or its connection. Similarly, insufficient circulation does not prove that the pump has failed. These distinctions matter before buying a replacement part: the code guides diagnosis but does not replace a technician’s checks.

CodeDescriptionCause or technical checkApplication
114Outdoor temperature unavailableOutdoor sensor missing, disconnected or faultyNimbus R32/R410A
420BUS power supply overloadPower supply and configuration of connected devicesR410A
701 / 702 / 703Flow temperature sensor fault in zones 1, 2 and 3, respectivelySensor or connection for the indicated zoneR410A
711 / 712 / 713Return temperature sensor fault in zones 1, 2 and 3, respectivelySensor or connection for the indicated zoneR410A
722 / 723Overtemperature in zones 2 and 3, respectivelyCheck zone temperature and operationR410A
730 / 732Upper or lower buffer tank sensor fault, respectivelySensor, connection or hydraulic layout; buffer charging blockedR32
731Buffer tank overtemperatureCheck hydraulic layout and temperature measurementR32
902Primary circuit flow temperature sensor faultDisconnected or faulty sensorNimbus R32/R410A
903Primary circuit return temperature sensor faultSensor or connectionR410A
923Heating circuit pressure errorPossible leak, faulty pressure switch or wiringNimbus R32/R410A
924Heat pump communication errorCommunication between TDM and Energy ManagerNimbus R32/R410A
927AUX input mismatchAuxiliary input configurationR32
928Incorrect energy supply lockout configurationConfiguration of the corresponding functionR32
933Flow temperature or primary circuit overtemperatureInsufficient flow or a sensor reading problemNimbus R32/R410A
934Domestic hot water cylinder sensor faultDisconnected or faulty sensorNimbus R32/R410A
935Domestic hot water cylinder overtemperatureCheck sensor and three-way valveNimbus R32/R410A
936Underfloor heating thermostat errorSafety thermostat, flow or configurationNimbus R32/R410A
937Water circulation errorCirculating pump, flow detection or hydraulic problemNimbus R32/R410A
938Cylinder anode errorAnode, connection, presence of water or configurationUnits with a cylinder
940Hydraulic layout not definedIncomplete system configurationNimbus R32/R410A
941 / 942HV IN1 or HV IN2 input not defined, respectivelyInput function not configuredR410A
944Overtemperature in cooling modeCheck circuit flowR410A
945Flow switch stuckCheck flow detection and circulating pumpR410A
955Insufficient circulation or water flow detection errorHydraulic checks and inspection of flow and return sensorsNimbus R32/R410A
958 / 959Buffer tank sensor fault or overtemperatureExact description varies by manual; buffer charging blockedR410A
970Incorrect auxiliary pump or system type configurationWording and parameters vary by modelNimbus R32/R410A
971Split/monobloc configuration or outdoor version not definedIncomplete configuration; may remain in the history after a 30-second warningR410A

Configuration faults deserve particular attention if they appear after installation, the addition of heating zones or a circuit board replacement. That provides diagnostic context, but it does not authorise changes in the installer menu. Parameters describe how the system is built; changing them without checking the installation may hide the warning while leaving an incorrect configuration.

The outdoor unit and differences between R32 and R410A

The outdoor unit houses the compressor, fan and refrigerant circuit components. Its protections may respond to temperature, pressure, power supply or communication problems. The inverter is the electronics that regulates the compressor; an associated error requires interpretation of the recorded details, not an immediate conclusion that the board needs replacing.

Codes 910, 922, 950 and 951 show why generation identification matters. Differences also exist between models using the same refrigerant. Where a description changes, the table preserves that distinction rather than presenting a potentially false equivalence. Sensor abbreviations are retained to make comparison with the unit’s manual easier.

CodeDescriptionCause or diagnostic scopeApplication
905Compressor control errorControl fault; diagnosis required if it persistsNimbus R32/R410A
906 / 909Fan control error / zero fan speedOutdoor fan operation or controlNimbus R32/R410A
907 / 908Four-way valve / expansion valve control errorControl of the corresponding valveNimbus R32/R410A
910Communication error with a generation-dependent meaningR32: between inverter and TDM. R410A: communication with the heat pumpConfirm generation
911 / 916TE / TEO sensor errorCorresponding sensor or connectionR410A
912Four-way valve errorInspection and technician reset requiredNimbus R32/R410A
913 / 914LWT / TR sensor errorTemperature measurement; LWT refers to leaving water temperatureNimbus R32/R410A
915TDM communication errorElectronic communicationR410A
917Freezing errorTemperatures triggering protection; technician reset requiredNimbus R32/R410A
918Refrigerant recovery or pump-down cycle errorFailure of the corresponding cycleNimbus R32/R410A
919SDT condensing temperature too highTemperature outside the operating limitR410A
922R32: freezing. R410A: SST evaporating temperature too lowTemperature protection; user reset is provided for R32Confirm generation
931Inverter errorSubcode needed to identify the specific faultNimbus R32/R410A
939Outdoor unit errorCheck the outdoor unit’s detailed error informationNimbus Plus S Net R410A
946Compressor errorCheck compressor operation and frequencyNimbus Plus S Net R410A
947Four-way valve errorUser reset permitted; recurrence requires diagnosisNimbus R32/R410A
948 / 949 / 952TD / TS / TO sensor errorIndicated sensor or connectionR410A
950R32 Plus S Net: compressor discharge sensor fault. R410A: TD overtemperatureModel-dependent description; R410A requires technician resetPlus S Net R32 and R410A
951R32 Plus S Net: TD sensor fault. R410A: TD overtemperatureConfirm description and reset requirements in the specific manualPlus S Net R32 and R410A
953Compressor crankcase heater control errorControl of the corresponding heaterR410A
954Drain pan heater or model configuration errorMeaning varies; Compact M Net lists model configurationR410A
956 / 957Incompatible compressor / fan configurationMatch between components and configurationNimbus R32/R410A
960EWT sensor errorEntering water temperature measurementNimbus R32/R410A
962Defrost errorFault in the frost removal processNimbus R32
968ATGBUS communication errorCommunication between TDM and Energy ManagerR32
989Unit discharged errorRefrigerant circuit diagnosis; technician reset requiredPocket M Net and Compact S Net R32
994Low refrigerant charge errorUser reset permitted, not work on the refrigerant circuitPlus S Net R32
997 / 998Compressor overcurrent997: power-related reset specified in manual. 998: technician resetR32
9E5High-pressure switch trippedRefrigerant circuit pressure protectionR32
9E8 / 9E9Low-pressure switch / thermal protector error with compressor stoppedCheck the corresponding protective deviceR32
9E18ST1 safety thermostat errorCheck the device and the cause of activationR32
9E21 / 9E22Low refrigerant charge / unit dischargedRefrigerant circuit diagnosis; 9E22 requires technician resetR32
9E24 / 9E25Electronic expansion valve stuck9E24: user reset. 9E25: technician reset, on Pocket and Compact R32R32, model-dependent
9E28 / 9E29High-pressure protection9E28: user reset. 9E29: technician resetR32
9E31 / 9E32Compressor thermostat protection9E31: user reset. 9E32: technician resetR32
9E34 / 9E35Low-pressure protection9E34: user reset. 9E35: technician resetR32
9E36 / 9E37Current imbalance between compressor phases9E36: user reset. 9E37: technician resetR32
9E38 / 9E39Excessively abrupt change in compressor current9E38: user reset. 9E39: technician resetR32

A high or low refrigerant pressure code cannot be resolved by adjusting heating water pressure. Nor does a low-charge warning establish, without testing, how much refrigerant is missing or where the problem lies. Refrigerant circuit work, electrical measurements and access to internal components belong to a qualified technician.

2P warnings also need context

The 2P family covers different situations: domestic hot water production, backup heaters, precirculation and configuration. The whole group must not be treated as a simple reminder. Code 2P2, for example, means that thermal disinfection has not reached the required temperature within six hours, not that the treatment has been completed successfully.

Using hot water during disinfection or BOOST operation may prevent the cylinder from reaching its target. Avoiding consumption during the cycle is an operating check, not a repair. If the warning recurs, hot water production and electric backup need inspection; permanently disabling the anti-legionella function is not an appropriate workaround.

CodeDescriptionCause or checkApplication
2P2Thermal disinfection incomplete after six hoursDemand during the cycle or a heating problem; check backup heating if persistentNimbus R32/R410A
2P3BOOST fails to reach the target temperatureHot water consumption during the cycle or a production problemNimbus R32/R410A
2P4Electric heater thermostat activationCheck flow, circulating pump and thermostat; manual reset on R32 and automatic on R410AConfirm version
2P5Electric heater thermostat activationCheck flow, circulating pump and thermostat; automatic reset on R32 and manual on R410AConfirm version
2P6Reduced-rate tariff contact not configuredConfiguration mismatchR410A
2P7Precirculation errorFlow detection problem; on R410A, no flow detected for five minutesNimbus R32/R410A
2P8Low water pressure warningPossible leak, pressure switch or wiring faultR32
2P9Incomplete SG Ready configurationInconsistent configuration of energy management inputsNimbus R32/R410A

Codes 2P4 and 2P5 require particularly careful reading: the link between code and reset type changes between generations. A manual reset mentioned in the documentation does not necessarily mean there is a user-accessible button. If it requires opening a casing or accessing a heater, it is outside the scope of household checks.

923 and 2P8 allow inspection, not blind topping up

With these warnings, the safe check is to read the pressure gauge or the pressure shown on the interface and look for visible drips. You can visually inspect the area around the indoor unit, radiators and underfloor heating manifold without loosening fittings. A photograph of the reading, noting whether the system was cold or running, provides useful diagnostic information.

There is no universal filling pressure for every Nimbus installation. The correct pressure depends on the design and the manufacturer’s and installer’s instructions. The 1 to 1.5 bar range found in many boiler guides must not automatically be applied to a heat pump. Without a specific reference, it is safer to check the intended pressure than add water by guesswork.

An apparently normal pressure does not rule out the fault: the pressure switch or its wiring may send an incorrect signal. If the reading repeatedly falls, the loss needs investigation; if it stays stable but the warning persists, pressure detection needs checking. Neither situation justifies bypassing the protection, removing hydraulic filters or working on pressurised water.

If there is water near electrical connections, do not touch the wet area or open the appliance to locate the source. The leak and the installation’s safety need professional assessment. Repeatedly topping up to keep the unit running should also be avoided: it restores a reading but may leave the cause of the loss unresolved.

An authorised reset does not remove the cause

The documentation distinguishes between an interface reset, a reset involving interruption of power and a reset reserved for a technician. These are not interchangeable options. Permission to reset one code does not authorise applying the same method to another, opening electrical panels, removing covers or handling protective devices in the electrical installation.

Users may operate the normal controls or the interface reset function where their model’s manual permits it. For cases described as HP Power OFF, the manufacturer’s specific instruction must be followed; no procedure for manipulating the power supply is provided here. Unless it is clearly defined as an accessible user operation, it belongs to authorised personnel.

If the same code returns after the permitted reset, repeating it does not provide a diagnosis. Before clearing a warning, photograph the display and note whether it appeared during hot water heating, space heating, cooling or after a power cut. Recording simultaneous codes also matters: a protective response may be the consequence of an earlier fault.

A layer of frost or a paused fan does not, by itself, establish a fault. However, code 962 identifies a defrost problem and needs attention if persistent. You can look for objects externally blocking airflow without inserting hands, tools or water into the unit. Ice must not be removed by striking the heat exchanger fins.

Nuos has its own fault table

Nuos produces hot water using a heat pump and a storage tank; it must not be confused with a Nimbus space-conditioning system. The following table applies specifically to Nuos Plus S2 Wi-Fi with R290. It must not be extended to every Nuos generation, which may use different references and diagnostic systems.

On this range, some faults stop the heat pump while allowing the electric heater to continue. That explains why hot water may still be available even though the appliance has not recovered. Continued service does not guarantee unchanged energy consumption: resistance heating is not equivalent to normal heat pump operation. Whether that mode can remain in use must be checked against the manual and the relevant diagnosis.

CodeDescriptionCause or check
007Condenser sensor faultOpen circuit or short circuit; electric heater may continue with heat pump stopped
008 / 009 / 010 / 012Discharge / air / evaporator / suction sensor fault, respectivelyOpen circuit or short circuit in the corresponding sensor
021Refrigerant lossRefrigerant circuit diagnosis by qualified personnel
032Compressor problemTechnical inspection of compressor and power supply
042Evaporator obstructedVisually check air inlets and outlets with the appliance switched off
044Fan problemElectric heater and heat pump stop; technical inspection required
051High pressureCheck pressure switch and refrigerant circuit
053Compressor thermal protector faultCheck protector and the cause of the fault
054No communication with inverterRestart according to manual; check communication if persistent
218 / 230Upper hot water / heater area water sensor faultOpen circuit or short circuit
231 / 232Overtemperature at flange area sensorsTwo protection levels; technical inspection required
233Relay stuckManual provides for pressing ON/OFF twice; board diagnosis if persistent
241Impressed current anode open circuitPresence of water, anode or electronics; do not dismantle the tank
314Repeated switching on and offWait 15 minutes before unlocking with ON/OFF
321Corrupted dataTwo ON/OFF presses specified in manual; electronic inspection if persistent
331 / 332No communication between board and displayReset with two ON/OFF presses as specified; inspect if persistent
333No communication with Wi-Fi boardModule, communication or configuration
334No communication with TDCElectronic communication diagnosis
335No communication with safety boardReset with two ON/OFF presses as specified; inspect if persistent
336Touchscreen not workingReset with two ON/OFF presses as specified; interface diagnosis if persistent
337Cascade master appliance missingSystem configuration by the installer

For code 042, household checks end at accessible grilles and ducts: spotting a blocked inlet does not require opening the refrigerant circuit. R290 is a flammable refrigerant, and any work involving it belongs to a qualified professional. Sensors, flanges and tank heaters must not be removed in an attempt to confirm an internal fault.

A diagnosis that avoids replacing parts by elimination

Deciding what to do next requires the full model, exact code, recurrence and operating behaviour. A 931 without a subcode or a 939 without outdoor unit details leaves the diagnosis incomplete. In these cases, the technician needs the additional information before attributing the problem to the compressor or a circuit board. An error display is not a repair estimate.

There is no verified tariff that assigns a price to each code in these tables. Cost depends on the confirmed cause, access and required components. Before authorising work, establish the scope of diagnosis, the call-out charge and whether that amount will be deducted from any subsequent repair. Do not assume that the visit is included.

If the appliance may be covered by a warranty, keep photographs and maintenance records before authorising dismantling or buying parts. The applicable conditions should be checked with the party managing that coverage. Opening the unit unnecessarily does not improve the available information and may complicate assessment of what happened; an external, documented inspection provides a clearer starting point.

Whether the system can remain in use depends on the warning and what its manual expressly permits, not on the code disappearing for a few minutes. Recurring protection, a leak or a refrigerant circuit fault requires diagnosis before normal operation resumes. The aim is not simply to clear the screen, but to confirm that the installation is back within its operating conditions.