Roca boiler won’t ignite: causes, codes and what to check

Dead display, lockout or code: what the user can check on a Roca boiler and when it is time to call the engineer.

Published

on

Caldera Roca que no enciende en una vivienda con calefacción

A Roca boiler that refuses to start can be in one of three very different situations: the panel stays completely dark, the appliance starts up but locks out and leaves a number on the display, or everything seems normal and yet the burner never produces a flame. Working out which of the three you are facing halves the problem, because a total lack of signal points to the electrical supply, a lockout with a code means a safety device has tripped, and the absence of a flame usually has to do with the gas, the water pressure or a command that is not arriving from the thermostat.

If you have a problem with your boiler, you can use our free error code finder. There you can find out about and fix all errors easily and effectively.

Dark panel, lockout with a number or burner with no flame

The case that causes the most bewilderment is the boiler that has been idle for months and, when the cold returns, shows not a single light or indicator. That total absence of signal almost never has to do with gas or water: it means that no power is reaching the electronics or that something on the board itself has stopped responding. So the first thing is to check, from the outside and without touching the inside, that the socket, the switch and the circuit breaker in the home are as they should be. If there is power and the panel is still dead, the cause is inside the appliance and that is where the authorised engineer’s territory begins.

The second scenario is the lockout. The boiler switches on, the display lights up and, after a few seconds or a few minutes, a code appears and everything stops. Roca boilers are now made by the Baxi group, so the meaning of each warning is looked up in that company’s documentation. On the Roca Laura, for example, the warning is a two-digit number that works as a direct diagnosis, with no letters or combinations of lights.

The third is the quietest: the appliance seems to be in order, but the burner does not light. Three factors matter here. One is a lack of gas, whether a closed valve, an empty cylinder or a supply cut. Another is low pressure in the circuit, which prevents start-up for safety reasons. The last is a thermostat that does not pass on the order to heat. These are modest causes, and the usual thing is to rule them out in a few minutes without opening anything.

Power, gas and thermostat: what can be ruled out in a few minutes

With the panel dark, the power supply is the first stop. The boiler receives power through a socket or a fixed connection, and in both cases there is a main switch on the appliance and a circuit breaker in the home’s fuse box that may have tripped during the months of inactivity or after a storm. If the circuit breaker is reset and trips again immediately, what the user can do ends there: it indicates a leakage somewhere and is a job for an electrician or an authorised engineer, never a reason to keep trying.

When the panel does light up but the boiler does not start, it is time to check the fuel. On a mains gas installation it is enough to verify that the gas valve is open and that there is no supply cut; on a bottled gas installation, that the cylinder has not run out; on an oil installation, that the tank still has some fuel in it. It seems trivial, but it is one of the most frequent explanations after long periods of inactivity, because many homes close the valve at the end of winter and nobody remembers it in October.

The third link is the one that tells the boiler to work. A room thermostat in the wrong mode, with a set temperature below the actual temperature in the living room or with flat batteries, leaves the appliance waiting for an order that never comes. You need to confirm that it is in heating mode, that the programmed temperature is higher than the actual one and, if it is wireless, that the batteries are new even if they look good. On models with a summer/winter selector, the selector must be in the winter position, a setting that is easily forgotten after a season without heating.

After months of inactivity: pressure, a seized pump and air in the system

A heating boiler does not take neglect well. The water in the circuit cools down, the pressure may drop and the circulation pump, which has not turned for months, may have seized. All of this fits the pattern of the boiler that refuses to start precisely the first time it is switched on in autumn.

The reference is the pressure gauge, that dial with a needle or digital indicator that is usually on the front or on the underside. When cold, the right pressure is around 1 to 1.5 bar; below 0.8 or 0.9 bar the boiler will not start for safety reasons and, on the Roca Laura, it reports this with code 03. Topping up the circuit is an operation that the manufacturer allows the user to carry out, but it must be done following the model’s manual to the letter, without improvising. And if it has to be repeated every few days, the problem is no longer one of pressure but of a leak or an expansion vessel that has lost its pre-charge, so that water escapes through the safety valve. Diagnosing and repairing that is a job for an authorised engineer.

The other typical consequence of a long shutdown is the overheating codes: 06 when it trips with no flame and 14 when it does so with the burner lit. The clixon, a safety device that cuts out if the water gets too hot, reacts to the water not circulating as it should. The first suspect is air trapped in the system, which is why the sensible course is to bleed the radiators with the boiler off before thinking of replacing anything. If the warning reappears after bleeding, the seized pump becomes the most likely candidate, although a heat exchanger clogged with limescale produces the same symptom. In both cases, work on the pump or the heat exchanger is a job for the engineer.

There is a complementary symptom that helps narrow things down. If the taps run hot water but the radiators stay cold, suspicion shifts to the three-way valve, which sticks and always diverts the water to the domestic hot water circuit. Noises also give information: knocking suggests air or a stuck pump, gurgling calls for bleeding, and a whistling or crackling sound may indicate water on electrical parts, in which case the prudent course is to cut the power to the boiler and call a professional immediately.

Roca Laura codes 01 to 27 and what usually fails behind each one

The list that follows applies to the Roca Laura, and it is worth checking your model before applying it. The Laura 20 and Laura 30 use 01 to 24 and the Laura 35 adds three more, up to 27. The Laura Plus, on the other hand, has its own list, which goes up to 37, and should not be read with this table. Numbers 16 and 18 do not appear in the official list for any Laura, so if one of them seems to appear, the display has most probably been misread.

The table gives the meaning of each number according to the manufacturer’s documentation and, next to it, the part that most often lies behind it. That column is a guide and not a definitive diagnosis. The last column gives the safe check when there is something the user can do; for the rest, the limit is the casing: beyond it, an authorised engineer steps in.

CodeDescriptionProbable causeWhat the user can do
01Domestic hot water sensor faulty or wiring problemNTC sensorAuthorised engineer
02Heating sensor faulty or wiring problemNTC sensorAuthorised engineer
03Lack of pressure in the heating circuitWater loss, filling loop or expansion vesselRead the pressure gauge and follow the manual; if it recurs, engineer
04Flame relay not working properly or switched offCircuit boardAuthorised engineer
05Fault in the safety circuit: the boiler must be resetCircuit boardReset once; if it returns, engineer
06Overheating clixon open with no flameCirculation pump or air in the circuitBleed the radiators with the boiler off; if it returns, engineer
07Flue gas clixon open with no flamePressure switch or flue gas thermostatDo not reset without finding the cause; engineer
08Safety fuse openCircuit boardAuthorised engineer
09Power failure at the gas solenoid valves. Reset and check the gasGas valveCheck the valve and supply; if it persists, engineer
10Fault in the safety relay: does not close after the demandCircuit boardAuthorised engineer
11Burner off: ignition timing too shortCircuit boardAuthorised engineer
12Ignition lockout: gas or spark may be missingGas valve or electrodeCheck the valve and supply; then engineer
13Safety relay: ignition timing too longCircuit boardAuthorised engineer
14Overheating clixon open with flame. ResetCirculation pump or air in the circuitBleed the radiators with the boiler off; if it returns, engineer
15Flue gas clixon open with flame. ResetFlue fanAuthorised engineer
17No gas while running, or total or partial electrical fault. ResetGas valveCheck the valve and supply; if it persists, engineer
19Pressure above zero at the flue gas pressure switch or thermostatFlue gas pressure switchAuthorised engineer
20Insufficient pressure at the flue gas pressure switch or thermostatFlue gas pressure switchCheck that the outside outlet is not blocked; engineer
21Safety relay open in the temperature controlCircuit boardAuthorised engineer
22Leak or dripping at a hot water tapTaps in the home, not the boilerCheck that no hot water tap is dripping
23Internal board error: communication failure between microprocessorsCircuit boardAuthorised engineer
24Faulty wiring or poor contact in the control panel pinsWiring and connectorsAuthorised engineer
25Domestic hot water and cold water sensors swapped or loose (Laura 35 only)NTC sensorAuthorised engineer
26Modulating valve wrongly connected or fault in the control panel (Laura 35 only)Gas valveAuthorised engineer
27Inconsistency between the values measured by the microprocessors (Laura 35 only)Circuit boardAuthorised engineer

Outside the Laura, the equivalences get more complicated. The Roca Victoria 20/20 shares its electronics with it and therefore has the same faults with the same description, but shows them with combinations of lights instead of numbers. On other generic lists of Roca boilers, codes such as E1 or E02 circulate for low pressure and 50, 60 or 90 for excess temperature, while other lists place 40, 50, 90, H.02.06 or E10 under the lockout for insufficient pressure on the Victoria. As the sources do not agree, none of those equivalences should be taken as valid without checking it against the manual for the exact model.

Gas, flue gases, sensors and board: how to read the codes that come up most

The ignition lockout, code 12, is the one that most resembles the symptom of a boiler that won’t light. It signals that gas or spark was missing, and the only thing the user can verify is what has already been covered: that the valve is open and that there is a supply. If there is gas, the next suspect is the electrode and, after that, the gas valve. Replacing it is part of the gas circuit and is done by an authorised engineer, without exception.

Codes 07, 15, 19 and 20 point to flue gas evacuation. The flue gas pressure switch is the usual suspect, especially when the small silicone tubes have hardened or are full of condensation, and on room-sealed versions the fan also counts. These are safety devices that prevent the boiler from running without clearing the flue gases properly, so they are not reset without looking for the cause.

With the sensors, codes 01, 02 and 25, the lesson is that the fault may not be in the sensor. Damp or rust on the connector gives exactly the same symptom as a faulty sensor, and 25 has a surprising origin: the hot and cold water sensors swapped or loose, something that happens after a badly done installation or repair. Checking it means opening the appliance, so it is left to the engineer.

That leaves the circuit board, with which the table associates codes 04, 05, 08, 10, 11, 13, 21, 23 and 27. When power, gas, pressure and circulation have been ruled out and the warning belongs to that family of relays, timings, communication between microprocessors or inconsistent values, suspicion of the electronics gains weight. A reset may clear the message, but not the cause that produced it.

Resetting sensibly: how many times, and what happens if the lockout is ignored

Before restarting, you should note down the number that appears, because it disappears when you reset and the best clue available is lost. It is also worth noticing whether the fault trips on start-up or with the boiler already running: 06 and 14, or 07 and 15, are distinguished precisely by that, and the difference guides the engineer.

Resetting once to rule out a one-off fault is reasonable. Resetting over and over fixes nothing, and when the same number comes back after that reset it is time to stop trying and look for the cause. With gas and flue gas faults, moreover, persisting is dangerous: each reset forces the appliance to attempt an ignition that the safety device had blocked for a specific reason.

From this it follows how far the boiler can go on being used in the meantime. If the warning was for low pressure and the cause has been resolved, there is no reason to leave it switched off. If it was for gas, flue gases or overheating, the sensible thing is to keep it off until an authorised engineer has checked it: that is preferable to making a flue gas fault worse or forcing a pump that no longer turns.

When the code points to the symptom and not the cause

A code says which safety device has tripped, not why. Code 03 reports that pressure is low, but not whether the water is escaping through a leak or through the safety valve. 06 and 14 speak of overheating, and behind them there may be air, a seized pump or limescale in the heat exchanger. And 22 does not even point to the boiler: it points to a dripping hot water tap in the home.

That is why buying the part listed as the suspect and replacing it is a bet with a poor ratio of cost to success. The probable cause column describes what is found most often, not what is wrong with that particular appliance, and replacing a sensor, a gas valve or a circuit board means working on electricity, gas and water. The prudent course is to reach the engineer with the code noted down and no parts replaced, so that the diagnosis starts from clean data.

Smell of gas, leaks and other signs that cannot wait

There are situations in which nothing is tested. If you smell gas, you close the stopcock immediately, ventilate the room, do not operate any electrical switch and notify the gas distributor or the emergency services. None of the checks described above makes sense before that is dealt with.

The same goes for water. A major leak means shutting off the mains water supply, and a visible drip on the boiler, or pressure that keeps falling after topping up, indicates a loss that only an authorised engineer can locate. Added to this are the whistling or crackling noises already mentioned, which justify disconnecting the appliance from the power and not starting it up again until it has been checked.

Repair or replace: the criterion that matters more than the price of the part

Faced with a fault that won’t go away, the decision whether to repair or replace the appliance depends on three variables. The first is age: a boiler that is more than ten years old and has frequent faults deserves to have its replacement with a more efficient model considered. The second is the component: a sensor or a connector is a fault of a different order from a gas valve, a pump or a circuit board, which are the ones that push up the bill most.

The third is proportion. Rather than a fixed figure, what is useful is to compare the quote with the price of an equivalent new model: when the repair approaches a substantial part of that amount and the appliance already has years and faults behind it, the balance tips towards replacement. It is advisable to ask for the quote to itemise parts, labour and call-out, and to find out before the visit whether its cost is deducted from the repair or charged separately.

That leaves the matter of the guarantee. Opening the appliance yourself may put it in question, which is why you should read the terms of the guarantee or the maintenance contract before taking anything for granted. In any case, the inside of a boiler contains gas, pressurised water and live components: it is not an area for the user, whether or not cover is in force. Annual servicing, which includes cleaning the burners and heat exchangers and checking combustion, detects minor faults before they get worse.

What information to give the authorised engineer

The visit is more productive when the engineer receives precise information. You need to state the exact model, which is on the rating plate, because a Laura 20, a Laura 35, a Laura Plus and a Victoria 20/20 are not read in the same way, and the code as it appeared, specifying whether it tripped on start-up or with the boiler already running.

It also helps to describe the symptom clearly, for example that the radiators don’t heat up but the hot water does, and to give details of what has already been checked: the pressure the gauge showed, the thermostat batteries, the gas valve, the bleeding of the radiators and the electrical supply. One last useful point is whether the fault appears only with the boiler cold after hours of inactivity or only after it has been running for a while.