Connect with us

Magazine

Heating Start-Up: 3 Plumber-Approved Steps in 10 Minutes

Bleed radiators, check boiler pressure and check valves: a plumber’s steps before the cold sets in.

Published

on

Radiador de calefacción en una casa con caldera de gas al fondo

Image: Erik Mclean / Pexels

The heating start-up when the cold arrives can be done in 10 minutes and requires checking that the boiler pressure is between 1 and 1.5 bar when cold, according to plumber Joan Pascual, who posts on TikTok as @elfontaJoan. Pascual, who has years of experience in the trade, sums up in three steps what is worth checking before switching the system on for the first time this season.

With the cold autumn days under way, even if some days are still a little warm for the time of year, more and more people are switching on their heating for the first time in months. The three steps are bleeding the radiators, checking the boiler, and checking the valves and thermostatic heads. These are tips from a professional, not a technical standard.

Bleed the radiators so you don’t pay to heat air

Radiators heat rooms through a closed circuit of hot water. When they go a long time without being used, they tend to build up air inside, which usually reduces their efficiency and increases energy use.

That is why the first step is bleeding. Pascual warns what happens if you skip it: “If you don’t do it, the air stays inside and you end up with cold at the top and heat at the bottom.” He adds: “You’re using gas to heat air.” According to the plumber, rooms take longer to reach the desired temperature and you notice it on your gas bill.

The bleed valve is the small valve at the top corners of the radiator. Bleeding is only necessary on radiators with a manual bleed valve and is done with a flat-head screwdriver. A slight hiss means it is open enough and the trapped air is escaping. Keep it open until the first drops of water appear, a sign that the circuit is free of gas. Then close it with the same screwdriver, slowly, to avoid large amounts of water spilling out.

Boiler pressure: 1 to 1.5 bar when cold

The second step is checking the boiler. Pascual recommends a pressure “between 1 and 1.5 bar when cold. If it’s below that, top it up with the filling loop.” This valve is usually on the underside of the boiler, between the connecting pipes.

To top up, open the valve slowly, check that water is coming in, watch the gauge and close it quickly once it reaches between 1 and 1.5 bar. Once you have checked that the valve is fully closed, you can switch the boiler back on and confirm that the pressure is as recommended. It is worth repeating the check the next day, with the appliance cold again.

When to suspect a fault

If you have to top up again, it is advisable to note how many times you do it each month. If it is more than three times a month, the circuit may have a fault or a leak and it is worth calling a technician.

Valves, heads and other efficiency tips

The third step is to check that the radiator valves are open and, in Pascual’s words, “that no part is dripping.” If the radiator has a thermostatic head, check that it is not stuck. These checks help the heating work properly and allow the home to warm up more quickly.

Pascual adds two efficiency tips: let the sun in during the morning and close the blinds at night to insulate the home, and do not cover the radiators, because it can reduce their output.

Airing your home in winter without building up damp

Germany’s Federal Environment Agency (Umweltbundesamt) says that in winter it is best to open the windows a couple of times a day for 5 minutes. The WHO notes that many symptoms of respiratory problems, such as asthma or allergies, are linked to damp and mould in buildings, often the result of poor ventilation.

The usual advice is to air the home when you get up, at midday and before going to bed, and this can be adapted to the household’s routine; the most recommended time is in the morning. For it to be effective, it is advisable to open opposite windows and let a draught through for 5 or 10 minutes.

In a bathroom with a window, open it right after the shower, because of the condensation from the steam. In the kitchen, open the windows during and after cooking, with the kitchen door closed. If a room is colder than the rest, it is advisable to keep its door closed to avoid condensation in corners or behind furniture.

This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.

Most read