Connect with us

Baxi

Baxi boiler code 117: what it means and what to check

What 117 means on modern Baxi boilers, what to check safely and when to call an authorised technician.

Published

on

Caldera mural de gas en una vivienda con aviso de presión del agua

The 117 code on a Baxi boiler belongs to the family of water pressure warnings for the heating circuit: it does not point to the gas or the ignition, but to whether the water running through the radiators is at the pressure the appliance needs in order to work. It is shown by the more recent Baxi platform, the models that number their faults with three digits, and it shares a family with 118. The first check, and the only one that is really essential before calling anyone, is to look at the pressure gauge on the boiler itself.

If you have a problem with your boiler, you can use our free error code finder. From there you can find out what is wrong and fix all your errors easily and effectively.

What 117 means and why it does not apply to every Baxi

Baxi wall-hung boilers with a digital display have a self-diagnosis system that turns each fault into a code. According to the brand’s technical documentation, the full catalogue runs to more than a hundred different codes, and that has a practical consequence: a number only means something specific within the range that produces it. In the material consulted, 117 is classed among the water pressure warnings, alongside 118, within the three-digit numbering that Baxi uses in its most recent appliances.

That numbering coexists with others. On the Neodens 24/24 F, the Novanox, the Neobit and the Roca boilers of that generation, an ignition failure appears as E01; on the ECO range and the Platinum Compact, that same fault is called 133 and comes with 128, 129 and 134. On the Victoria Condens, meanwhile, the warnings are organised in groups with H and E prefixes followed by a specific code. That is three different languages within a single brand, which is why it pays to identify the range before taking anything for granted.

On the three-digit ranges, 117 indicates that the circuit pressure is too high and 118 that it is too low. The boiler’s pressure gauge and the manual for your specific model, whether it is a Platinum Plus 32 AF or another, which Baxi publishes in Spanish, are what count.

Baxi codes that get confused with 117

When the display lights up with a number, readers tend to match what they see against what they remember from other faults. The table below brings together the codes that the sources place close to 117, with one warning: each row applies only to the range indicated, and the Victoria Condens pressure warnings are included as a reference for how Baxi treats this type of fault, not as an equivalent of 117.

CodeDescriptionCause or line of checkingRange
117Circuit pressure too highFilling loop open or letting water through, expansion vessel with no charge, pressure relief valveThree-digit platform
118Circuit pressure too lowLeak, recent bleeding or a pressure relief valve that is dischargingThree-digit platform
128Loss of flameNot detailed in the sourcesECO and Platinum Compact
129Loss of flame at ignitionNot detailed in the sourcesECO and Platinum Compact
133No ignition after 5 attemptsGas tap closed, air in the pipework, dirty or worn electrode, gas valve or circuit boardECO and Platinum Compact
134Gas valve blockedNot detailed in the sourcesECO and Platinum Compact
E01Lockout due to ignition failure (equivalent to 133)The same causes as 133Neodens 24/24 F, Novanox, Neobit and Roca
H.02.06Low heating circuit pressureCheck and restore the pressure, check the expansion vessel, look for leaksVictoria Condens
E.02.07Permanent low heating circuit pressureThe same lines of checking as H.02.06Victoria Condens

The most useful thing about this table is the separation of territories: the ignition warnings (133, E01) are about gas and spark; the pressure ones (117, 118, H.02.06, E.02.07) are about water. If the screen shows a three-digit number other than those above, the answer is in the manual for that model, not in an extrapolation.

What the user can check without opening anything

A useful check starts with the simplest thing: the pressure gauge reading, the small circular or bar indicator that almost all boilers have on the front. If the needle or indicator is clearly outside the working zone given in the manual, the warning is explained; if it is inside, the code may be a one-off incident, and a simple restart from the boiler’s own control helps to confirm it. This is a harmless operation, but it should not be repeated in a loop: a restart does not change the water pressure, it only lets you see whether the warning comes back.

Around the appliance there are more clues that only require looking. A puddle, a damp patch or a drip under the boiler, at the visible connections or under the radiators suggests that water is being lost somewhere. The recent history also counts: installations tend to show water problems when the heating season starts, after a repair, after a leak or after bleeding the radiators, because each of those actions alters the amount of water in the circuit.

Topping up the circuit with mains water is the obvious temptation when the pressure drops, and each model describes it in its user manual. Here it is worth setting the limit: handling filling loops, the expansion vessel or any element of the hydraulic circuit is a job for the installer or the authorised service technician, especially if there are doubts about what the warning means. Opening the casing to see what is going on inside is not a check for the home user either.

Pressure that rises or falls: the symptom is not the cause

A pressure warning describes what the boiler measures, not why it is happening. With 117, the cause is usually a filling loop that has been left open or an expansion vessel that has lost its charge; with 118, a water leak. The lines of checking that Baxi associates with low pressure on the Victoria Condens make this clear: after restoring the pressure, you must check the expansion vessel and look for leaks in the boiler or in the installation. In other words, adding water is only a patch if the water is escaping or if the circuit’s pressure buffer is not doing its job.

A very practical decision criterion follows from this. If the warning appears once after bleeding radiators or after some work, it is normally a side effect of that operation. If the warning returns days or weeks after the pressure has been normalised, the problem is no longer one of pressure: the cause is in the circuit (a filling loop that lets water through, an expansion vessel with no charge or a pressure relief valve that is discharging), and repeating the operation only delays the diagnosis. The sources do not set an acceptable number of top-ups, so the reasonable rule is that the warning coming back is already reason enough for a visit.

It is also worth not confusing this family with the ignition warnings. The Baxi manual allows up to five consecutive reset attempts after an ignition failure, with a fifteen-minute wait afterwards, because there a restart may clear air in the gas pipe. With a water warning the logic is the opposite: resetting does not restore pressure, and each attempt only confirms what the pressure gauge already says.

Using the boiler while the technician is on the way

A pressure code is, above all, a protective measure: the boiler stops working or limits its operation because the circuit is not in a fit state. Forcing it, insisting on resets or looking for shortcuts is not a way of gaining time, but of adding variables to a fault that can still be narrowed down with a clear pressure gauge reading. If the appliance can run normally after the pressure has been restored, that is a sign that the cause was the recent operation; if it locks out again, it is better to leave it switched off.

When an authorised technician must step in

The limit comes at the point where the check requires touching the circuit: filling, draining, measuring the expansion vessel, locating an internal leak or opening the casing. All of that is the work of an authorised technician, and even more so when the boiler is still under guarantee. The three-year legal guarantee (Spain) applies to appliances bought from 2022, and it is worth reading the conditions before a third party or the user opens the appliance, because not doing so is the simplest way of not complicating a cover that might apply.

Before the visit, it is worth asking whether the call-out charge is deducted from the repair quote or charged separately, and having to hand the details that shorten the diagnosis: the exact code shown on the screen, the range and model given on the rating plate, the pressure gauge reading and the moment the warning appeared, whether after bleeding radiators, after a supply cut or for no apparent reason.

This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.

Most read