Ferroli boiler won’t start: error codes and likely causes
Why a Ferroli boiler stops, what its codes mean and how far a user can safely go with checks.

A Ferroli that won’t start is usually in one of three situations: it is not receiving power and the display stays dark, it is receiving power but the burner cannot establish a flame, or the electronic board has cut the ignition for safety and is showing a code that begins with A or F. Working out which of the three it is comes first, because the first can sometimes be put right with a check around the house, the second depends on the gas, the ignition and the flue, and the third means reading the code before pressing anything else.
If you have a problem with your boiler, you can use our free error code finder. There you can find out what is wrong and fix any error easily and effectively.
Three scenarios behind a boiler that has stopped
When the display shows no sign of life, the fault is almost never in the boiler itself. The sensible thing is to check whether the RCD or the circuit breaker in the home has tripped, whether the socket has power (test it by plugging in another appliance) and whether the appliance’s own switch is in the on position. Resetting the breaker once is acceptable; if it trips again, the problem is electrical and is a job for an electrician or the installer. The Bluehelix range also has codes F34 and F35, which warn of a supply voltage below 170 V or an abnormal mains frequency: they concern the mains supply, not the burner.
The second scenario is the most baffling: the display lights up, the fan can be heard and perhaps even the click of the ignition, but the flame does not appear or goes out after a few seconds. Here code A01, which the sources describe as the burner failing to light, is the reference. The causes they list are no gas, a fault in the detection or ignition electrode, a faulty gas valve and ignition power that is too low; some tables add low water pressure, a blocked condensate trap and a blocked flue. A06 is similar: it means there is no flame after the ignition phase, and it is declared when this happens six times in four minutes.
The third scenario is lockout. When the board detects something it doesn’t like, it stops trying, and each press of the reset button simply repeats the same attempt. That is why the range includes codes A64 and F64, which show that the maximum number of consecutive resets has been exceeded; the manufacturer’s instruction is to cut the boiler’s power supply for 60 seconds and then reconnect it. Carrying on pressing reset without waiting fixes nothing and, if the fault is with the gas or the flue, only multiplies the number of failed ignition attempts. If the boiler locks out repeatedly with the same code, the prudent course is to leave it switched off until an authorised engineer has seen it, rather than using it on and off to see whether it holds out.
Safe checks before assuming the fault is serious
The first check is the most obvious and the one most often forgotten: the gas isolation valve. After building work, an inspection of the installation, or a change of gas cylinder or meter, it may have been left closed. It is enough to see whether the other gas appliances in the house are working. If you smell gas, the approach changes completely: close the valve, ventilate the room, do not operate any switch or use any naked flame, and call the distributor’s emergency service. That is strictly a job for professionals.
The second check is the heating circuit pressure. The usual reference for a domestic boiler is between 1 and 2 bar, and the pressure gauge measures the closed heating circuit, not the domestic hot water. Below 1 bar, the heating does not work or works poorly and the hot water may come out lukewarm at the taps. The two typical causes are a leak in the boiler or in part of the circuit, and a recent bleed of the radiators that has left the system short of water. In the second case, the manual for each model explains how to top up the water with the filling loop, taking care that the needle does not go past 2 bar; if the pressure drops again within days, there is a leak and an installer needs to look at it. Codes F20, F37 and F51 point to this area.
That leaves the room thermostat, the great forgotten suspect. Flat batteries, a changed time schedule or a broken wire between the thermostat and the boiler produce exactly the symptom of a boiler that does not respond to demand. Changing the batteries and checking the schedule is within anyone’s reach. So is bleeding the radiators with the key that comes with each one, which also helps with overtemperature alarms, which often start with air in the circuit. Anything that involves opening the boiler casing, touching wiring or touching the pump is outside what a user should do.
Bluehelix range codes and what each one means
The fault tables published by manufacturers and installers for the Bluehelix RRT models, including the Bluehelix Tech RRT 24 C, help to narrow the problem down. The meanings hold for this Ferroli range; other models from the brand use different lists, so the manual for your appliance takes priority. The last column marks how far a user can check things safely and where an authorised engineer takes over.
| Code | Description | Cause given in the sources | What the user can check | Who steps in |
|---|---|---|---|---|
| A01 | Burner does not light | No gas, detection or ignition electrode, gas valve, low ignition power; in some tables, low pressure, blocked trap or blocked flue | Gas valve open, supply, pressure on the gauge | Authorised engineer (electrode, valve, ignition power) |
| A02 | Flame signal with the burner off | Fault in the ionisation electrode or the board | A single restart | Authorised engineer |
| A06 | No flame after the ignition phase (6 times in 4 minutes) | Ionisation electrode, unstable flame, blocked air and flue ducts, blocked trap | That the external flue and air terminals are not visibly blocked | Authorised engineer |
| A07 and F03 | High flue gas temperature | Heat exchanger, flue gas sensor, chimney material parameter | Nothing accessible | Authorised engineer |
| A08, A09, F04, F09, F16 | Overtemperature protection | Flow or return sensor, circulator, air in the system | Bleed air from the radiators | Authorised engineer (sensor and circulator) |
| A11 | Gas valve connection | Wiring or valve | Nothing accessible | Authorised engineer |
| A13, F13, F17 | Fault in the flue gas probe or sensor | Wiring or faulty probe | Nothing accessible | Authorised engineer |
| A23, A24, A26, F47 | Fault in the water pressure switch | Pressure outside limits, connection to the water supply, filling valve, control relay | Pressure on the gauge | Installer or authorised engineer |
| F20, F37, F51 | Water pressure too low or incorrect | Lack of water in the circuit or faulty pressure sensor | Gauge between 1 and 2 bar; any visible leaks | Installer if the pressure drops again |
| F21, F40 | Water pressure too high | Filling valve, control relay, expansion vessel | Gauge reading | Authorised engineer |
| F05 | Fan fault | Wiring of the 5-pin connector or faulty fan | Nothing accessible | Authorised engineer |
| F10, F11, F12, F14, F22 | Fault in the flow, return or domestic hot water sensors | Faulty sensor, short circuit or broken wiring | Nothing accessible | Authorised engineer |
| F34, F35 | Voltage below 170 V or abnormal mains frequency | Problems with the electricity supply | Whether other appliances in the house fail or flicker | Electrician or electricity company |
| F41, F43 | Thermal jump or heat exchanger protection | Circulator, lack of circulation, air in the system | Bleed the radiators | Authorised engineer |
| A54, A55, A63 | Control unit fault | Control board failure | Switch the boiler off for 10 seconds and back on | Authorised engineer if it persists |
| A62 | No communication between the control unit and the gas valve | Control unit disconnected, wiring or faulty valve | Nothing accessible | Authorised engineer |
| A64, F64 | Maximum consecutive resets exceeded | Lockout after a chain of faults | Cut the power for 60 seconds and reconnect, once only | Authorised engineer if it reappears |
| A65, A97, F65, F98 | Combustion control errors | Blocked flue ducts or trap, gas pressure, need for calibration or board | Nothing accessible | Authorised engineer |
| A80 | Parasitic flame signal after the valve closes | Electrode, electronic board or gas valve | Nothing accessible | Authorised engineer |
It is worth reading this table with one idea in mind: the internal parameters, calibrations and replacement of parts mentioned in the manuals, such as the b06, b11 or b15 settings or the full manual CO2 calibration, are work reserved for technical staff. The fact that a service manual describes them does not make them a household task. For the user, the table is mainly useful for putting a name to the fault and knowing whether it is worth a visit.
When the tables do not agree with each other
Anyone comparing two lists of errors for the same range will find differences, and it is not a misreading. The fan appears as F05 in one table and as A05 in another, and in the latter it is linked to low voltage or an interruption of the tachometer signal. High flue gas temperatures appear as A07, F03, F15 and F18 in some sources and as F07, F14 and A07 in others, so that A14 refers to F03 or to F07 depending on the document. The overtemperature protection is spread across F04, F08, F09 and F16 with different nuances.
Another discrepancy affects codes A23, A24, A26, F20, F21, F40, F47, F50, F51 and F53. One source treats them as faults in the water pressure switch, the pressure or the limit thermostat, and another as a generic fault in the board parameters. This may be because firmware revisions and the different models and outputs in the range change the numbering. That is why the only reliable reference is the manual for the exact model, which can be found using the reference on the data plate, and not a generic table copied from another boiler.
In practice, the discrepancy leads to a simple recommendation: write down the code exactly as it appears and the time at which it appears, and do not deduce from memory a fault that then turns out not to fit.
Heating off while the hot water works
There is one particular case that causes confusion: the taps give hot water normally, but the radiators do not warm up and the boiler stops when the heating demand comes in. The usual causes point to the heating circuit and not the burner: a seized circulation pump, a faulty filling or inlet valve, a heating temperature sensor that has tripped, a broken wire between the thermostat and the boiler, or a faulty room thermostat.
Freeing a pump, changing a sensor or replacing a valve are jobs for an installer, even though some guides on the internet explain them as if they were DIY-shop jobs. In the meantime, if the hot water works, there is no smell of gas, there are no leaks and no overtemperature or flue code appears, using the boiler only for domestic hot water is a reasonable option; if it keeps locking out, it is better to switch it off.
A note of context on room-sealed and condensing boilers: the fan or turbine draws in the air for mixing with the gas and expels the combustion gases. If it stops working, the boiler cannot start under any circumstances, which is why code F05 is one of those that does not allow waiting.
Oil burners: starting up under different rules
Not all Ferrolis run on gas. On oil-fired models with a separate burner, such as those in the GNTK series, the symptom is different: the burner does not start, no red alarm light comes on and the control box receives power but does not give the go-ahead to start. Before suspecting the electronics, there are two risk-free checks: that the oil valves are open and that the tank has enough fuel.
If at the same time there is a smell of fuel, smoke or soot, switch the appliance off and call a professional.
Why the code does not always point to the faulty part
A code describes the symptom, not necessarily the cause. An A01 can arise from a closed gas valve, an electrode with scale on it, a blocked trap or a faulty valve, and each costs very different amounts. Replacing parts in order of suspicion can make the repair more expensive without solving anything. The sensible course is to ask the engineer for a diagnosis that identifies the faulty part and, if possible, to have it set out in writing before anything is replaced.
The decision to repair or replace the boiler depends on three variables: the age of the appliance, the part affected and the proportion that the repair cost represents of the price of an equivalent new appliance. A sensor, an electrode or a probe are usually contained faults; a control board, a gas valve or a heat exchanger weigh much more. When several different faults follow one another in an already older boiler, or when the repair approaches the cost of a new appliance, the balance starts to tip towards replacement. With a quote in hand, that proportion is the best yardstick.
It is also worth asking beforehand whether the call-out and the diagnostic inspection are deducted from the repair cost if you accept it, or charged separately: this is a policy that changes from one service provider to another and is usually clarified when the appointment is made, not when the invoice arrives.
Before opening the appliance: warranty, maintenance and the visit
One of the doubts that most holds back people with a boiler that has stopped is whether handling it will make them lose the warranty. The conditions vary according to the manufacturer and the contract, but removing the casing or working on internal components may fall within the exclusions of many warranties, and above all of maintenance contracts. The recommendation is to read those conditions before anyone opens the appliance, and to check which actions require an authorised installer. Do not assume that a restart or bleeding the radiators are prohibited interventions: they are operations intended for the user.
The same approach applies to a boiler with a periodic service contract: if the fault coincides with a recent operation, the service that carried it out is the first point of contact. And if the fault involves gas, flue, combustion or internal electrics, the limit is not administrative but one of safety: the work is for an authorised engineer even if there were no warranty involved.
Information to have to hand when the engineer arrives
A visit is more productive if you arrive with the information in order. It helps to note the exact model of the boiler, which appears on the data plate, the code that appears and at what moment (as soon as you press on, after a few ignition attempts, when heating is called for or when a hot tap is opened), and whether the fault has been continuous or intermittent.
It is also worth noting the pressure gauge reading, whether the hot water works normally even though the heating does not, how many resets have been done and when, what work or replacements were carried out beforehand, and whether there was a smell of gas, strange noises or visible leaks.
This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.
Magazine3 days agoWashing machine smells? Clean the seal and leave the door open
Robot aspirador7 days agoDreame robot vacuum error codes: causes and fixes
Magazine7 days agoXiaomi launches Mijia home appliances in Spain: prices
Robot aspirador7 days agoRoborock error codes: what they mean and what to do
Magazine6 days agoEU Right to Repair Directive: What Manufacturers Must Now Do
Junkers6 days agoWhy your Junkers water heater will not ignite and what to check
Boiler7 days agoBoiler leaking underneath: causes and what to do
Magazine4 days agoPellet stove shutting down: causes and safe checks
Magazine6 days agoUnderfloor heating not warming up: causes and safe checks
Magazine7 days agoMehmet Tüfekçi named new managing director of Beko Europe in Spain
Magazine5 days agoEU E-Waste Levy Could Cost Spain Over €1,800 Million a Year
Heat pump5 days agoHeat pump water flow error: causes and safe solutions