Baxi boiler won’t start: causes, codes and what to check
What lies behind a lockout on Baxi boilers, which codes announce it and how far you can safely check things yourself.

A Baxi wall-mounted boiler that fails to start almost always does so for one of four reasons: no gas is reaching the burner, the flame is not detected, the water in the circuit does not have the right pressure or circulation, or the flue gas evacuation does not give the safety signal. The display usually indicates which of them it is with a code, and that code means something different depending on the appliance’s range.
If you have a problem with your boiler, you can use our free error code finder. There you can find out what is wrong and fix any error easily and effectively.
The code on the display rules: what each lockout means
Before touching anything, it is worth looking at the display. Baxi does not use a single numbering system: the older Neodens and Neobit models show codes of two or three digits, with or without the letter E in front (E01, 110, E119); the recent condensing range, such as the Neobit Condens or the Platinum Max Plus, uses codes with dots of the type H.01.05 or E.04.10, where H warns of a temporary fault and E of a permanent lockout. Carrying the meaning from one range over to another is the quickest way to get the diagnosis wrong.
The ignition fault most searched for is E01. On the Neodens 24/24 F, the Novanox and the Roca models of the same generation, it means lockout due to ignition failure: the boiler tries to start, detects no flame and locks out. On the ECO range and the Platinum Compact, the same symptom appears as 133, no ignition after several attempts, and is often accompanied by codes 128 (flame loss), 129 (flame loss during ignition) and 134 (gas valve blocked). There is one discrepancy worth mentioning: one source speaks of six attempts for E133 in the Novadens manual and another of five on the ECO range, so the exact number depends on the model.
Other lockouts that leave the boiler without heating or hot water have nothing to do with the gas but with the water. A 118 indicates too low a pressure in the circuit, a 117 too high a pressure, a 110 overtemperature due to lack of circulation and a 125 the safety device tripping because of a lack of water or air in the system. And those related to the fan, such as 160, point to the extractor not reaching the required speed.
| Code | Description according to the manual | Usual cause | Who acts |
|---|---|---|---|
| E01 | Lockout due to ignition failure (Neodens 24/24 F, Novanox and Roca of the same generation) | No gas, air in the pipe, dirty electrode or gas valve | User: gas valve and reset; engineer: electrode and valve |
| 133 / E133 | No ignition after several attempts | Gas valves closed or incorrect live/neutral polarity | User: valves and reset; engineer: polarity and gas |
| 110 / E110 | Safety thermostat for overtemperature | Seized pump, air in the circuit or closed valves | User: radiator valves and reset; engineer if it reappears |
| 118 / E118 | Pressure too low in the heating circuit | Leak or loss of pressure | User: fill to 1.5 bar; engineer if there is a leak |
| 117 / E117 | Pressure too high (more than 2.7 bar) | Filling valve not fully closed or expansion vessel | User: check the valve; engineer if it persists |
| 125 / E125 | Lack of water circulation or air in the system | Pump, air or closed valves | Reset with the selector on R; engineer if it persists |
| 160 / E160 | Fan speed threshold not reached | Fan or its connection | Authorised engineer |
| H.02.04 | Board parameters unreadable | Board configuration lost | Authorised engineer |
The first things anyone can check
If the boiler does not respond, the logical order goes from the simplest to the most complex. First, that there is a supply: check that the gas isolation valve for the home is open and that other gas appliances are working, because a supply cut or air in the pipe after an interruption causes exactly this ignition lockout. Then look at the pressure gauge: with the system cold it should read between 1 and 1.5 bar, and below 0.5 bar almost any boiler locks out for lack of water.
Resetting is the best-known check and also the most misunderstood. According to the Baxi manual, you press the reset button for at least two seconds, and on the ECO range only five consecutive resets are allowed; after that the boiler stays locked out and you have to wait 15 minutes to try again. If the second attempt fails with gas present, insisting does not help: the reset clears the warning, not the fault, and each failed attempt brings the appliance back to the same point.
With pressure faults, the user can act: with the boiler cold, slowly open the filling loop until it reaches 1.5 bar and close it fully. If you have to top up every few weeks, there is a leak in the radiators, pipes or the boiler itself, and the code will come back until a professional locates it. Topping up non-stop is not harmless either: it lets air into the circuit.
When the problem stops being a household matter
Flame, ionisation and gas valve codes are the exclusive territory of the authorised gas installer. Cleaning or replacing the ignition electrode means getting inside the boiler, and the same goes for the gas valve, the fan or the board. Even what appears to be a simple removal of the fan is not advisable, because it involves the combustion chamber and its seals, which must be left properly sealed when reassembled.
There is also a sign that does not allow waiting: if you smell gas, ventilate the room, close the isolation valve and do not operate any switch or use the telephone inside the home until you are out. Likewise, reversed live-neutral polarity, cited by some sources as a cause of E01, is corrected in the electrical installation and is not something the user should improvise with the boiler connected.
A practical question that holds many people back is whether opening the appliance themselves affects the warranty. Although the conditions vary, the prudent course is to check what the contract or the boiler’s certificate says before handling anything: intervention by unauthorised personnel is usually precisely the reason cover is lost and, in a gas appliance, it is also a safety risk.
Carrying on using it or leaving it off
An ignition lockout is a safety function, not damage in itself. Even so, forcing successive resets can hide a growing fault. With overtemperature codes, such as 110, the documentation itself warns that if it returns the same day you should not reset any more: the boiler is protecting itself from genuine overheating, with the circulation pump among the suspects.
Noting when the error appears is a great help to the engineer: whether it happens on ignition, when hot water is called for or after a few minutes, the pattern indicates whether the culprit is the ignition, the circulation or the pressure. With the code, the exact model and that detail, the visit will be much shorter.
As for whether it is worth repairing or replacing, the criterion depends on the age of the boiler and the part affected: an electrode or a probe are modest spares, whereas an electronic board or a heat exchanger can bring the bill up to a significant fraction of the price of a new appliance. It is worth asking for a detailed quote and comparing it with the cost of an equivalent appliance before deciding; on a model with many years behind it, repeated faults cost more than a planned replacement.
What to do if the code is not on the list
Baxi and Roca share a history, but not all their ranges use the same list: the same number can mean something else on another model. That is why it is advisable to check the exact model on the data plate and compare the code with the corresponding user manual, without accepting a generic meaning as valid.
This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.
Magazine3 days agoWashing machine smells? Clean the seal and leave the door open
Magazine7 days agoXiaomi launches Mijia home appliances in Spain: prices
Robot aspirador7 days agoRoborock error codes: what they mean and what to do
Magazine6 days agoEU Right to Repair Directive: What Manufacturers Must Now Do
Junkers6 days agoWhy your Junkers water heater will not ignite and what to check
Magazine4 days agoPellet stove shutting down: causes and safe checks
Boiler7 days agoBoiler leaking underneath: causes and what to do
Magazine6 days agoUnderfloor heating not warming up: causes and safe checks
Magazine7 days agoMehmet Tüfekçi named new managing director of Beko Europe in Spain
Magazine5 days agoEU E-Waste Levy Could Cost Spain Over €1,800 Million a Year
Heat pump5 days agoHeat pump winter consumption: electricity use and running costs
Magazine5 days agoPellet stove won’t start: causes and safe solutions