Fagor boiler that won’t start: causes, codes and fixes
From a closed gas valve to the pressure switch: what lies behind a locked-out Fagor boiler and how far the user can go.

A Fagor boiler that won’t start is almost never simply dead: more often it has locked out for safety and announces it with a steady red light and a code on the display. On the FE and CE series, F1 indicates an ignition failure, which is usually due to gas not arriving or circulating mixed with air; F2 is linked to the combustion air and the flue, and F3 points to the heating circuit pressure. If, on the other hand, the display is completely off, suspicion shifts to the electricity supply or the control board.
If you have a problem with your boiler, you can use our free error code finder. There you can find out what is wrong and fix any error easily and effectively.
Display off, red light or sparks with no flame: three different faults
Before looking for causes, it helps to know which of three situations the appliance is in, because each points to a different system. The first is the lockout with a code: Fagor boilers in the FE and CE series have a fault indicator which, on any anomaly, stops operation, lights the red lockout light and shows the corresponding code on the digital display. The second is the boiler that tries to light and fails: you hear the buzz or the spark, but no flame appears and the amber burner-on light does not come on, and after several attempts it ends up locked out. The third is the one that gives no sign of life at all, with no display and no lights.
On these models, unlocking is designed for the user: just turn the main switch to position O and return it to its previous position. If the fault was a one-off, the red light goes out, the display shows the pressure again and the boiler returns to the state it was in before the fault. If it remains locked out, the manufacturer says to contact the nearest technical assistance service and warns that tampering with the appliance can cause an accident.
A real case illustrates the third situation. A user of a Contract Mini CE-24E reported that, after unplugging it for more than an hour and plugging it back in, the boiler still showed nothing. Disconnecting and reconnecting is equivalent to a full restart, so when even that does not bring the display back, the problem is no longer a temporary lockout of the logic but a lack of power or an electronic fault, which is covered further down.
Fagor FE and CE boiler error codes and what each one means
The published references for the FE-24E, FE-27E, FE-30E and CE-30E models describe a family of codes beginning with F that indicate which system has detected the fault. The table gives the most common ones together with the check that any user can do without opening the appliance; where no household check is possible, the last column says so plainly.
| Code | Description | Usual cause | What the user can check |
|---|---|---|---|
| F1 | Ignition failure | Gas mixed with air after first start-up, a long shutdown or a cylinder change; gas valve closed; in other cases, dirty electrode or faulty servo valve | That the gas valve is open and the cylinder is not empty; unlock once or twice |
| F2 | False pressure: air pressure switch fault | The pressure switch does not detect air flow or is faulty | Look for visible obstructions in the flue outlet or the air intake; watch whether the fan runs non-stop |
| F3 | Heating circuit pressure out of range | Pressure below 0.6 bar or above 2.8 bar; air or obstructions in the circuit | Read the pressure on the display, which should be above 1 bar, and call the engineer if it does not recover |
| F4 | Safety thermostat cut-out | The safety thermostat has tripped and the boiler locks out | None; requires an authorised engineer |
| F5 | Control board fault | Internal fault in the electronic circuit | None; requires an authorised engineer |
| F6 | False pilot | The amber burner-on light comes on with the burner off | None; requires an authorised engineer |
| F10 | Gas valve control fault | Fault in the valve control; it cannot be unlocked | None; requires an authorised engineer |
| F11 | Domestic hot water thermistor fault | Temperature sensor in the domestic circuit; the boiler locks out | None; requires an authorised engineer |
| F13 | Main heat exchanger outlet thermistor fault | Heat exchanger temperature sensor; the boiler locks out | None; requires an authorised engineer |
Two points help in reading the table. The first is that the code indicates the system that failed, not necessarily the part at fault: an F1 can be due to a closed gas valve, air in the pipe or a dirty electrode, and only the order of the checks separates one cause from another. The second is that the list comes from the models cited; the CE-24E belongs to the same range, but a code means what its manufacturer says for its specific series, so it is worth confirming it in the model’s manual before taking it for granted.
F1, the ignition failure that most often recurs after changing the cylinder
F1 means the boiler has tried to light the burner several times without success. Either gas may be lacking or the spark may be failing. It appears mainly on first start-up or after a long shutdown, because the gas filling the pipework is mixed with air and that weak mixture makes ignition difficult. The same happens when changing a cylinder or after recent work on the installation.
The sensible sequence starts with the simplest thing: check that the gas isolation valve is open and, if the supply is from a cylinder, that it has not run out. If there is another gas appliance in the house, checking that it works rules out a general supply problem. Then comes unlocking from the main switch, watching the complete ignition attempt; one or two attempts are enough to purge the excess air. If the warning persists, the suspects are a dirty, wet or worn ignition electrode, a faulty servo valve or deteriorated ignition wiring, and all of them belong to the gas and combustion circuit, so they are checked by a qualified installer.
A reasonable question remains: how many times is it prudent to unlock. The lockout is itself the safety measure, because the boiler stops trying so as not to release gas without burning it, so while it remains locked out there is no added risk. But insisting when the air should already have been purged achieves nothing: if F1 reappears at every attempt after one or two unlockings, a component is most likely faulty and repeating the restart will not fix it. If at any point you smell gas, you must ventilate, close the isolation valve and call a professional before trying anything again.
F2 and F3: combustion air, flue gases and circuit pressure
F2 appears when the air pressure switch does not detect flow or when the pressure switch itself fails. This sensor confirms that the fan is moving air through the intake and exhaust duct before allowing the gas to burn; without that confirmation, the boiler refuses to light. What the user can check, with the appliance switched off, is whether there is a visible obstruction in the flue outlet or the air intake, such as a blocked external terminal, and whether the fan runs continuously, something worth passing on to the engineer. Touching the pressure switch or its tubes is not a household check.
F3 is the pressure warning. The boiler locks out if the heating circuit falls below 0.6 bar or exceeds 2.8 bar, and the manufacturer recommends that the figure on the display stays above 1 bar. When, on trying to light, it does not detect enough flow, the pump stays active for five minutes, in cycles of 30 seconds on and 5 off, without locking the boiler out, until it senses flow. The causes include air in the circuit and obstructions, and both bleeding and restoring the pressure must follow the procedure in that model’s manual; if the pressure drops again after correcting it, there is a leak that a professional must locate, because it involves working with pressurised water.
When the display does not light: power supply and control board
With no display and no lights, the diagnosis is shorter. The first thing is to confirm that power is reaching the boiler: that the plug is firmly in, that the socket works with another small appliance and that the home’s supply has not been cut off. If the protection in the consumer unit trips repeatedly, the check is a job for an electrician, not for resetting it again and again. Some generic guides on Fagor heaters also mention faults in the power supply, a relay or the solenoid valve, internal parts that only an engineer should touch.
Telling a board fault apart from the rest is not easy from outside, but there are clues. Code F5 describes an internal fault in the electronic circuit; a display that does not light despite power confirmed at the socket, or lockouts that repeat with no clear external cause, point in the same direction. These are indications, not verdicts: only an inspection with the right equipment confirms whether the culprit is the board, a sensor or the power supply, and opening the appliance while it is live is not an option for the user.
There are also intermittent faults that confuse. A boiler that locks out one day, is unlocked and works normally for weeks is usually down to something circumstantial, such as air after a cylinder change. One that repeats the warning on consecutive days is pointing to a deteriorating component, and carrying on unlocking it daily only postpones the inspection without touching the cause.
Fagor FEB boilers and other series: the red light speaks in flashes
Not all Fagor boilers show digital codes. Those in the FEB series, such as the FEB-20E, communicate faults through a red LED: each code begins and ends with the light steady for 5 seconds, and between them come one-second flashes whose number identifies the fault. A single flash corresponds to an air pressure switch fault, crossed tubes or a blocked flue venturi, similar to F2 on the FE and CE series, and code 6 indicates water overheating. Resetting is done with the reset button, not with the switch.
The manual for this series also says that, if the boiler has been off for a long time or a new cylinder has been fitted on propane models, there may be air in the pipes that causes it to shut down, and that repeating the ignition a few times is enough to purge it. It also sets a pressure of 0.75 to 1 bar when cold. Here a useful discrepancy appears: some users on forums advise raising it to 1.5 bar, a figure that does not appear in the FEB manual and does not fit the recommendation to exceed 1 bar on the FE and CE series. Each series has its own criteria, so the valid reference is the manual for the specific model and not the advice of a forum thread.
How far the user can go and when the authorised engineer steps in
The safe territory is broad, but it has a clear edge. Anyone can check that the gas valve is open, that the cylinder has not run empty, that the plug and socket work, that there are no visible obstacles at the flue terminal, that the pressure on the display stays within the stated range and that unlocking with the switch returns the boiler to its previous state. Beyond that, the electrode, servo valve, pressure switch, sensors, gas valve, burner and board are for a qualified installer or engineer.
It is wise to be wary of certain online guides that recommend removing the casing to clean the burners, replace a thermostat or clean the temperature sensor. On a gas appliance with a combustion chamber this is not household work, and besides safety, the warranty comes into play: the sources do not specify what conditions each manufacturer has, so the prudent course is to read the conditions and the maintenance book before opening anything, because unauthorised work can leave the owner without cover.
Repair or replace: how to assess what the quote says
The cost of a fault depends entirely on the part. Cleaning or replacing an ignition electrode is usually among the quickest and cheapest jobs, normally dealt with in a single visit, whereas a control board or a gas valve is another category. As a guide, more useful than a specific figure is the criterion: ask for an itemised quote, compare the total with the price of an equivalent new boiler and take the age of the appliance into account.
The proportion is the key. When the repair approaches a significant share of the cost of a new model, or when the boiler has accumulated several different faults, as the CE-24E user described, replacing starts to make sense even if the particular part is repairable. Before accepting the visit, it is worth asking whether the call-out charge is deducted from the repair cost or charged separately, whether the part is available and how long it takes to arrive, because the lead time varies by range and there is no general figure that allows it to be predicted.
Details to note down before the engineer’s visit
A quick diagnosis begins with a good description. Noting the exact model shown on the data plate, such as FE-24E, CE-24E or FEB-20E, avoids confusing the meaning of a code between series. Then, the code shown on the display or the number of flashes of the red light, whether unlocking with the switch or the reset button clears it and how many times it reappears, and whether the fault coincides with a cylinder change, a long shutdown or recent work on the installation.
It also helps to say what pressure the display shows, whether the fan runs without stopping, whether a buzz or spark is heard without a flame appearing, whether the amber burner-on light comes on, and whether the display stays off even though you have checked there is power at the socket.
This article contains affiliate links: if you buy through them, we earn a small commission at no extra cost to you. More information.
Magazine3 days agoWashing machine smells? Clean the seal and leave the door open
Magazine7 days agoXiaomi launches Mijia home appliances in Spain: prices
Magazine6 days agoEU Right to Repair Directive: What Manufacturers Must Now Do
Boiler7 days agoBoiler leaking underneath: causes and what to do
Junkers6 days agoWhy your Junkers water heater will not ignite and what to check
Magazine4 days agoPellet stove shutting down: causes and safe checks
Magazine6 days agoUnderfloor heating not warming up: causes and safe checks
Magazine7 days agoMehmet Tüfekçi named new managing director of Beko Europe in Spain
Electric water heater5 days agoElectric water heater timer: savings, schedules and safety
Heat pump5 days agoHeat pump winter consumption: electricity use and running costs
Magazine5 days agoEU E-Waste Levy Could Cost Spain Over €1,800 Million a Year
Magazine5 days agoBaby Brezza Recalls 29,000 Steriliser Dryers in the US